Skip to main content

2 x SAS/SATA + 2 x AnyBay backplanes

This section lists the required components for server models with 2 x SAS/SATA + 2 x AnyBay 3.5-inch hot-swap backplanes.

Note
  • Connections between connectors; 11, 22, 33, ... nn

  • When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.

  • Y-cables are shown as individual cables in the illustrations for each backplane.

  • Connect cables prioritizing Gen 4 RAID adapters.

  • For more information on the cables that are used, see Backplane cable list.

Onboard NVMe/SATA + 1 x 8i RAID/HBA

NVMe cable routing
Figure 1. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to MCIO x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 2. SAS/SATA cable routing to system board and PCIe slot 9
SAS/SATA cable routing to system board and PCIe slot 9
FromToCable
1 BP1: SAS/SATASATA 0-3 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
2 BP2: SAS/SATASATA 4-7 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 2 x 8i RAID/HBA

NVMe cable routing
Figure 3. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to MCIO x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 4. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 5. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 1 x 16i RAID/HBA

NVMe cable routing
Figure 6. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to MCIO x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 7. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 1 x 24i RAID/HBA

NVMe cable routing
Figure 8. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to MCIO x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 9. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)
2 BP2: SAS/SATA
3 BP3: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)
4 BP4: SAS/SATA

Onboard NVMe/SATA + 1 x retimer + 1 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 10. NVMe cable routing to system board and top PCIe zone
NVMe cable routing to system board and top PCIe zone
Figure 11. NVMe cable routing to system board and bottom PCIe zone
NVMe cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 12. SAS/SATA cable routing to system board and PCIe slot 9
SAS/SATA cable routing to system board and PCIe slot 9
FromToCable
1 BP1: SAS/SATASATA 0-3 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
2 BP2: SAS/SATASATA 4-7 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 1 x retimer + 2 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 13. NVMe cable routing to system board and top PCIe zone
NVMe cable routing to system board and top PCIe zone
Figure 14. NVMe cable routing to system board and bottom PCIe zone
NVMe cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 15. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 16. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 1 x retimer + 1 x 16i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 17. NVMe cable routing to system board and top PCIe zone
NVMe cable routing to system board and top PCIe zone
Figure 18. NVMe cable routing to system board and bottom PCIe zone
NVMe cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 19. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

Onboard NVMe + 1 x retimer + 1 x 24i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 20. NVMe cable routing to system board and top PCIe zone
NVMe cable routing to system board and top PCIe zone
Figure 21. NVMe cable routing to system board and bottom PCIe zone
NVMe cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1PCIe 3 (onboard)SlimSAS x8 to MCIO x8 pair (325 mm/160 mm)
4 BP2: NVMe 2-3PCIe 4 (onboard)
SAS/SATA cable routing
Figure 22. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)
2 BP2: SAS/SATA
3 BP3: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)
4 BP4: SAS/SATA

Onboard SATA + 2 x retimers + 1 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 23. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 24. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
4 BP2: NVMe 2-3Retimer: C1
SAS/SATA cable routing
Figure 25. SAS/SATA cable routing to system board and PCIe slot 9
SAS/SATA cable routing to system board and PCIe slot 9
FromToCable
1 BP1: SAS/SATASATA 0-3 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
2 BP2: SAS/SATASATA 4-7 (onboard)SlimSAS x4 to SlimSAS x4 (540 mm)
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

2 x retimers + 2 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 26. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 27. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
4 BP2: NVMe 2-3Retimer: C1
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 28. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 29. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

2 x retimers + 1 x 16i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 30. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 31. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
4 BP2: NVMe 2-3Retimer: C1
SAS/SATA cable routing
Figure 32. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (590 mm/590 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)

2 BP2: SAS/SATA
3 BP3: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x4*2 (840 mm/840 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)

4 BP4: SAS/SATA

2 x retimers + 1 x 24i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 33. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 34. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
4 BP2: NVMe 2-3Retimer: C1
SAS/SATA cable routing
Figure 35. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm)
2 BP2: SAS/SATA
3 BP3: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm)
4 BP4: SAS/SATA

2 x retimers + 1 x CFF RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 36. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 37. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP2: NVMe 0-1Retimer: C0SlimSAS x8 to MCIO x8 pair (700 mm/700 mm)
4 BP2: NVMe 2-3Retimer: C1
SAS/SATA cable routing
Figure 38. SAS/SATA cable routing to CFF RAID/HBA adapter
SAS/SATA cable routing to CFF RAID/HBA adapter
FromToCable
1 BP1: SAS/SATACFF RAID/HBA: C0SlimSAS x4 to SlimSAS x4 (260 mm)
2 BP2: SAS/SATACFF RAID/HBA: C1SlimSAS x4 to SlimSAS x4 (260 mm)
3 BP3: SAS/SATACFF RAID/HBA: C2SlimSAS x4 to SlimSAS x4 (720 mm)
4 BP4: SAS/SATACFF RAID/HBA: C3SlimSAS x4 to SlimSAS x4 (720 mm)