Replace the SD530 system board
Follow this procedure to replace the SD530 system board.
Procedure performed by: Solution administrator
To replace the SD530 system board from the ThinkAgile CP, perform these steps.
- Get the serial number and (optional) UUID information from Lenovo Cloud Controller.
- Remove the compute node from the D2 enclosure.
- Sign in to the primary interconnect through Support Mode or, if at a data center, using a method provided by the manufacturer. Sign in with user name admin and the password set during installation.
- Run the following command on the primary interconnect: sudo service tacp-network-controller restart.
- Follow the procedure at http://thinksystem.lenovofiles.com/help/index.jsp?topic=%2F7X21%2Fmaintenance_manual_hardware_replacement_procedures.html
- Insert the compute node back into the D2 enclosure.
- Wait 10 minutes and verify that the compute node is visible again in the web portal.
Give feedback