Thermal rules
This topic provides thermal rules for the server.
Server models with front and rear drive bays
This section provides thermal information for server models with front and rear drive bays.
| Drive bays | Front drives | 24 x 3.5-inch SATA |
| Rear drives | 2 x 2.5-inch NVMe | |
| Maximum ambient temperature support (fan normal) | 40°C (at sea level) | |
| Maximum ambient temperature support (fan fail) | 30°C (at sea level) | |
| Processor TDP | 350 W | |
| Air baffle type | Standard | |
| Heat sink type | 2U performance T-shape heat sink | |
| System fan type | 6038 | |
| DIMM | Type | Hynix DDR5 RDIMM 64 GB (2Rx4) |
| Maximum quantity supported | 16 | |
| OCP module | Install either one below:
| |
Server model with BF3 adapter
This section provides thermal information for server model with BF3 adapter.
| Drive bays | Front drives | 8 x 3.5-inch SATA |
| Rear drives | / | |
| Maximum ambient temperature support (fan normal) | 33°C (at sea level) | |
| Processor TDP | 330 W | |
| Air baffle type | Air baffle for BF3 | |
| Heat sink type | 2U performance T-shape heat sink | |
| System fan type | 6038 | |
| DIMM | Type | Hynix DDR5 RDIMM 64 GB (2Rx4) |
| Maximum quantity supported | 16 | |
| OCP module | / | |
| PCIe adapter | Nvidia BF3 900-9D3B6-00SV-AA0 FHHL 2x200G QSFP112 PCIe5x16 NIC | |
Give documentation feedback