FQXST0001W : The disk group is online but cannot tolerate another disk failure.

The disk group is online but cannot tolerate another disk failure.

Severity

Warning

Serviceable with log

No

Automatically Notify Support

Yes

User Action

Check to see if events 9 and 37 are logged.

  • If so, reconstruction automatically started.
    1. Replace the failed disk and configure the replacement as a dedicated (linear only) or global spare for future use. For continued optimum I/O performance, the replacement disk should have the same or better performance.
    2. Confirm that all failed disks have been replaced and that there are sufficient spare disks configured for future use.
  • If event 37 was not logged, a spare of the proper type and size was not available for reconstruction. Replace the failed disk with one of the same type and the same or greater capacity and, if necessary, designate it as a spare.