FQXST0309I : When the Management Controller (MC) is started, the IP data is obtained from the midplane FRU ID SEEPROM where it is persisted. If the system is unable to write it to the SEEPROM the last time it changed, a flag is set in flash memory. This flag is checked during startup, and if set, this event is logged and the IP data that is in flash memory is used. The IP data might not be correct if the controller module was swapped because the data in the controller's flash memory are used.

When the Management Controller (MC) is started, the IP data is obtained from the midplane FRU ID SEEPROM where it is persisted. If the system is unable to write it to the SEEPROM the last time it changed, a flag is set in flash memory. This flag is checked during startup, and if set, this event is logged and the IP data that is in flash memory is used. The IP data might not be correct if the controller module was swapped because the data in the controller's flash memory are used.

Severity

Informational

Serviceable with log

No

Automatically Notify Support

No

User Action

Information only; no action is required.