Skip to main content

FQXST0058W : A disk drive reset itself due to an internal logic error.

A disk drive reset itself due to an internal logic error.

Severity

Warning

Serviceable with log

No

Automatically Notify Support

No

User Action

  1. The first time this event is logged with a severity of Warning, update the disk firmware if the specified disk is not running the latest firmware.
  2. If this event is logged with severity of Warning for the same disk more than five times in one week, and the specified disk is running the latest firmware, replace the disk with one of the same type (SAS SSD, enterprise SAS, or midline SAS) and the same or greater capacity. For continued optimum I/O performance, the replacement disk should have performance that is the same as or better than the one it is replacing.