FQXST0469W : The speed of buses connecting the FPGA to downstream adapters was reduced to compensate for an FPGA over-temperature condition. The storage system is operational but I/O performance is reduced.

The speed of buses connecting the FPGA to downstream adapters was reduced to compensate for an FPGA over-temperature condition. The storage system is operational but I/O performance is reduced.

Severity​

Warning

Serviceable with log​

Yes

Automatically Notify Support​

Yes

User Action​

  1. Check that the fans in the storage system are running.
  2. Check that the ambient temperature is not too warm. The enclosure operating range is 5\ufffdC-40\ufffdC (41\ufffdF-104\ufffdF).
  3. Check for any obstructions to the air flow.
  4. Check that there is a module or blank filler in every module bay in the enclosure.
  5. Replace the controller module that logged the error.
When the problem is resolved, event 468 is logged.