FQXST0554W : A voltage sensor is not within the normal operating range but is within safe operating limits; or, a voltage sensor was removed.

A voltage sensor is not within the normal operating range but is within safe operating limits; or, a voltage sensor was removed.

Severity

Warning

Serviceable with log

No

Automatically Notify Support

Yes

User Action

If a voltage sensor has exceeded the normal operating range but is within safe operating limits:

  1. Check that all modules in the enclosure are fully seated in their slots and that their latches are locked.
  2. If this does not resolve the issue, the specified FRU has probably failed and should be replaced.
If a voltage sensor has been removed:
  1. Check that the specified FRU is in the specified enclosure.
  2. If the FRU is not in the enclosure, install the FRU immediately.
  3. If the FRU is in the enclosure, ensure that the FRU is fully seated in its slot and that its latches are locked.
  4. If this does not resolve the issue, the specified FRU has probably failed and should be replaced.

When the problem is resolved, an event with the same code will be logged with a severity of Resolved.