Drive bay limited exceeded
The storage array has exceeded the allowed number of drive bays. This problem typically occurs when you add an additional drive shelf after you already have the maximum number of drive bays allowed.
Recovery Steps
Did the drive shelf you recently added contain data?
If yes, go to step 2.
If no, remove the recently-added drive shelf and then go to step 3.
Do you need to transfer any of the existing data onto the storage array?
If yes, do NOT continue with the recovery steps. Contact a Technical Support Engineer to see if your storage array can be upgraded to a different feature to allow more drive bays.
If no, remove the recently-added drive shelf and then go to step 3.
If you altered your cabling configuration to add or remove the drive shelf, refer to your cabling documentation and ensure that you have the proper cabling configuration.
Select Recheck to ensure the problem has been resolved.