Six 2.5-inch-drive model (with NVMe)
Use this section to understand how to route cables for Six 2.5-inch-drive model (with NVMe).
Six 2.5-inch-drive model (with NVMe)
Note
If you are installing NVMe drives and KVM breakout module in the same compute node, make sure to route the KVM breakout module cable on top of the PCIe signal cable.
Figure 1. NVMe and KVM breakout module cable routing
1 KVM breakout module cable (routed to left side) | 2 NVMe signal cables |
Six 2.5-inch hot-swap SAS/SATA/NVMe backplane
Figure 2. Six 2.5-inch hot-swap SAS/SATA/NVMe backplaneTable 2. Components on the six 2.5-inch hot-swap SAS/SATA/NVMe backplane 1 Ambient sensor cable 3 Backplane power cable 2 miscellaneous signal cable Six 2.5-inch drive cable routing (with NVMe)
Figure 3. Six 2.5-inch drive cable routing (with NVMe)Table 3. Components on the six 2.5-inch drive cable routing (with NVMe) 1 NVMe cable 4 7 SAS/SATA cable 2 PCIe slot 3 connector 5 SATA 1 connector 3 8 Internal cable management basket 6 SATA 2 connector Six 2.5-inch drive (with NVMe) with hardware RAID cable routing
Figure 4. Six 2.5-inch drive (with NVMe) with hardware RAID cable routingNoteRoute the1 SAS/SATA cable as shown in the illustration to avoid cable slack. Table 4. Components on six 2.5-inch drive with hardware RAID cable routing 1 6 SAS/SATA cable 4 7 Internal cable management basket 2 NVMe cable 5 RAID adapter 3 PCIe slot 3 connector