Install components to the left wing of riser assembly

Follow instructions in this section to install components to the left wing of riser assembly.

About this task

S002
disconnect all power
CAUTION
The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • Touch the static-protective package that contains the component to any unpainted metal surface on the server; then, remove it from the package and place it on a static-protective surface.

Proceed to the section corresponding to the component to be installed:

Install M.2 assembly

Note
Make sure to observe the installation rules and sequence order in M.2 storage drive installation rules and order.

Procedure

  1. Install an M.2 drive to the M.2 cabled adapter.
    1. Locate the slot to install the M.2 drive.
      Top side of M.2 cabled adapter


      1 Slot 3 / M.2 Bay 2
      2 Slot 5 / M.2 Bay 4
      Bottom side of M.2 cabled adapter


      1 Slot 4 / M.2 Bay 3
      2 Slot 6 / M.2 Bay 5
    2. If necessary, install an M.2 heat sink to the M.2 drive to be installed. See Install an M.2 heat sink.
    3. If necessary, adjust the retainer to accommodate the size of the M.2 drive to be installed. See Adjust the retainer on the M.2 adapter.
    4. Hold the M.2 drive at an angle, and insert the drive into the M.2 slot.
    5. Lower the rear side of the M.2 drive down to the M.2 adapter.
    6. Secure the M.2 drive with one screw.
    Figure 1. Installing an M.2 drive
    Installing an M.2 drive
    Note

    If necessary, repeat this procedure to other M.2 drives to be installed.

  2. Install the M.2 cabled adapter to the riser cage.
    1. Route the M.2 cabled adapter signal cable through the hole in the middle of riser cage.
      Note
      For easier operation, route the branch of MCIO 1 connector first; then, route the branch of MCIO 2 connector.
      Figure 2. M.2 cabled adapter signal cable

      1 MCIO 1 connector2 MCIO 2 connector
    2. Connect the power cable to 2 Power connector 1 and 3 Power connector 2 on the M.2 cabled adapter.
      Top side of M.2 cabled adapter


      • 1 MCIO 1 connector
      • 2 Power connector 1
      • 3 Power connector 2
    3. Align the M.2 cabled adapter with the slot on the riser cage; then, slide the adapter into the slot until it is firmly seated.
    4. Secure the M.2 cabled adapter with six screws.
      Figure 3. Installing the M.2 adapter

    5. Connect the signal cable to the M.2 cabled adapter. Connect 1 MCIO 1 connector; then, connect 2 MCIO 2 connector.
      Figure 4. Disconnecting the signal cable

      1 MCIO 1 connector2 MCIO 2 connector

After this task is completed

  • Reinstall the riser assembly to the node. See Install the riser assembly to the node.

  • If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo Video

Watch the procedure on YouTube

Install PCIe assembly

Procedure

  1. Install the PCIe cabled riser card to the riser cage.
    1. Align the riser card with the guide pins on the riser cage; then, push the riser card towards the riser cage until it is firmly seated.
    2. Secure the riser card with two screws.
    Figure 5. Installing the riser card
    Installing the riser card
  2. Install the PCIe adapter to the riser cage.
    1. (Optional) If a PCIe filler is installed in the slot, loosen the screw that secures the filler; then, remove the filler. Save the filler for future use.
    2. (Optional) If the holder is secured on the riser cage, loosen the screw that secures the holder; then, remove and save the holder for later use.
    3. Align the PCIe adapter with the slot; then, carefully slide the adapter into the slot until it is firmly seated.
      Note
      Make sure not to let the adapter touch the edge of the riser cage.
    4. Secure the PCIe adapter with one screw.
    5. Insert the holder into the corresponding slot to cover the corner of the PCIe adapter; then, secure the holder with one screw.
    Figure 6. Installing the PCIe adapter
    Installing the PCIe adapter
  3. Connect the cables to the PCIe cabled riser card.
    PCIe cabled riser card


    • 1 Power connector
    • 2 MCIO 1 connector
    • 3 MCIO 2 connector

After this task is completed

  • Reinstall the riser assembly to the node. See Install the riser assembly to the node.

  • If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo Video

Watch the procedure on YouTube

Install drive backplanes

Procedure

  1. Install Backplane 1.
    1. Align Backplane 1 with the guide pins on the riser cage; then, lower Backplane 1 toward the riser cage until it is firmly seated.
    2. Secure Backplane 1 with three screws.
    Figure 7. Installing Backplane 1
    Installing Backplane 1
  2. Connect the signal cables to the backplanes.
    Backplane 1


    • 1 Backplane power connector
    • 2 NVMe 1 connector
    • 3 SATA connector
    Backplane 2


    • 1 NVMe 0 connector
  3. Install Backplane 2.
    1. Align Backplane 2 with the guide pins; then, lower Backplane 2 toward the riser cage until it is firmly seated.
    2. Secure Backplane 2 with four screws.
    Figure 8. Installing Backplane 2
    Installing Backplane 2

After this task is completed

  • Reinstall the riser assembly to the node. See Install the riser assembly to the node.

  • If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo Video

Watch the procedure on YouTube

Install PCIe assembly + geotracking module

Important
Geotracking module is a Third Party device. As such, third party options are excluded from Lenovo Statement of Limited Warranty. Engage third party for support. See ThinkEdge SE360 V2 Product Guide on Lenovo Press website for more information.

Procedure

  1. Install the PCIe cabled riser card to the riser cage.
    1. Align the riser card with the guide pins on the riser cage; then, push the riser card towards the riser cage until it is firmly seated.
    2. Secure the riser card with two screws.
    Figure 9. Installing the riser card
    Installing the riser card
  2. Install the PCIe adapter to the riser cage.
    1. (Optional) If a PCIe filler is installed in the slot, loosen the screw that secures the filler; then, remove the filler. Save the filler for future use.
    2. Align the PCIe adapter with the slot; then, carefully slide the adapter into the slot until it is firmly seated.
      Note
      Make sure not to let the adapter touch the edge of the riser cage.
    3. Secure the PCIe adapter with one screw.
    Figure 10. Installing the PCIe adapter
    Installing the PCIe adapter
  3. Install the geotracking module cage.
    1. Align the two tabs of geotracking module cage with the slots on riser cage; then, push the geotracking module cage toward the riser cage until it is seated in place. The edge of geotracking module cage should be inserted between the PCIe adapter and the riser cage.
      Figure 11. Installing the geotracking module cage
      Installing the geotracking module cage
    2. Push the geotracking module cage as shown until the two tabs are firmly seated in the slots.
      Figure 12. Installing the geotracking module cage
      Installing the geotracking module cage
    3. Secure the geotracking module cage with two screws.
      Figure 13. Installing the geotracking module cage
      Installing the geotracking module cage
  4. Install the geotracking module.
    1. Place one end of the geotracking module into the geotracking module cage.
    2. Lower the other end of the geotracking module into the geotracking module cage until it clicks into place.
    Figure 14. Installing the geotracking module
    Installing the geotracking module
  5. Connect the cables to the PCIe cabled riser card.
    PCIe cabled riser card


    • 1 Power connector
    • 2 MCIO 1 connector
    • 3 MCIO 2 connector

After this task is completed

  • Reinstall the riser assembly to the node. See Install the riser assembly to the node.

  • If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo Video

Watch the procedure on YouTube