Observable problems
See this section to solve observable problems.
The server immediately displays the POST Event Viewer when it is turned on
Complete the following procedure to solve the problem.
Correct any errors that are indicated by the light path diagnostics LEDs.
Make sure that the server supports all the processors and that the processors match in speed and cache size.
You can view processor details from system setup.
To determine if the processor is supported for the server, see ServerProven.
(Trained technician only) Make sure that processor 1 is seated correctly
(Trained technician only) Remove processor 2 and restart the server.
Replace the following components one at a time, in the order shown, restarting the server each time:
(Trained technician only) Processor
(Trained technician only) System board
Server is unresponsive (POST is complete and operating system is running)
Complete the following procedure to solve the problem.
If you are in the same location as the server, complete the following steps:
If you are using a KVM connection, make sure that the connection is operating correctly. Otherwise, make sure that the keyboard and mouse are operating correctly.
If possible, log in to the server and verify that all applications are running (no applications are hung).
Restart the server.
If the problem remains, make sure that any new software has been installed and configured correctly.
Contact your place of purchase of the software or your software provider.
If you are accessing the server from a remote location, complete the following steps:
Make sure that all applications are running (no applications are hung).
Attempt to log out of the system and log back in.
Validate the network access by pinging or running a trace route to the server from a command line.
If you are unable to get a response during a ping test, attempt to ping another server in the enclosure to determine whether it is a connection problem or server problem.
Run a trace route to determine where the connection breaks down. Attempt to resolve a connection issue with either the VPN or the point at which the connection breaks down.
Restart the server remotely through the management interface.
If the problem remains, verify that any new software has been installed and configured correctly.
Contact your place of purchase of the software or your software provider.
Server is unresponsive (cannot press F1 to start System Setup)
Configuration changes, such as added devices or adapter firmware updates, and firmware or application code problems can cause the server to fail POST (the power-on self-test).
The server restarts automatically and attempts POST again.
The server hangs, and you must manually restart the server for the server to attempt POST again.
After a specified number of consecutive attempts (automatic or manual), the server to reverts to the default UEFI configuration and starts System Setup so that you can make the necessary corrections to the configuration and restart the server. If the server is unable to successfully complete POST with the default configuration, there might be a problem with the system board.
You can specify the number of consecutive restart attempts in System Setup. Restart the server and press the key specified in the on-screen instructions to display the Lenovo XClarity Provisioning Manager system setup interface. Then, click . Available options are 3, 6, 9, and disable.
Voltage planar fault is displayed in the event log
Complete the following procedure to solve the problem.
Revert the system to the minimum configuration. See Specifications for the minimally required number of processors and DIMMs.
Restart the system.
If the system restarts, add each of the items that you removed one at a time, restarting the system each time, until the error occurs. Replace the item for which the error occurs.
If the system does not restart, suspect the system board.
Unusual smell
Complete the following procedure to solve the problem.
- An unusual smell might be coming from newly installed equipment.
- If the problem remains, contact Lenovo Support.
Server seems to be running hot
Complete the following procedure to solve the problem.
Multiple servers or chassis:
- Make sure that the room temperature is within the specified range (see Specifications).
- Check the management processor event log for rising temperature events. If there are no events, the server is running within normal operating temperatures. Note that you can expect some variation in temperature.
Cannot enter legacy mode after installing a new adapter
Complete the following procedure to solve the problem.
- Go to .
- Move the RAID adapter with operation system installed to the top of the list.
- Select Save.
- Reboot the system and auto boot to operation system.
Cracked parts or cracked chassis
Contact Lenovo Support.