UEFI events organized by severity
The following table lists all UEFI events, organized by severity (Information, Error, and Warning).
Event ID | Message String | Severity |
---|---|---|
FQXSFDD0008I | Self-Encrypting Drive (SED) Error: recovered from failure to get key. | Informational |
FQXSFDD0009I | Self-Encrypting Drive (SED) Error: recovered from failure to access drive [arg1]. | Informational |
FQXSFDD0010I | Self-Encrypting Drive (SED) Error: recovered from failure to unlock drive [arg1]. | Informational |
FQXSFDD0011I | Self-Encrypting Drive (SED) Error: recovered from failure to set password to drive [arg1]. | Informational |
FQXSFDD0012I | SATA Hard Drive Error: [arg1] was recovered. | Informational |
FQXSFIO0027I | The Bus:[arg1] Device:[arg2] Fun:[arg3] is attempted to boot PXE. | Informational |
FQXSFMA0001I | DIMM [arg1] Disable has been recovered. [arg2] | Informational |
FQXSFMA0002I | The uncorrectable memory error state has been cleared. | Informational |
FQXSFMA0006I | [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3]. | Informational |
FQXSFMA0007I | [arg1] DIMM number [arg2] has been replaced. [arg3] | Informational |
FQXSFMA0008I | DIMM [arg1] POST memory test failure has been recovered. [arg2] | Informational |
FQXSFMA0026I | DIMM [arg1] Self-healing, attempt post package repair (PPR) succeeded at Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7] | Informational |
FQXSFMA0027I | Invalid memory configuration (unsupported DIMM Population) recovered. | Informational |
FQXSFMA0029I | The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM. [arg2] | Informational |
FQXSFMA0030I | A correctable memory error has been detected on DIMM [arg1]. [arg2] | Informational |
FQXSFMA0065I | Multi-bit CE of DIMM [arg1] has been deasserted after performing post package repair. DIMM identifier is [arg2]. | Informational |
FQXSFPU0021I | The TPM physical presence state has been cleared. | Informational |
FQXSFPU0023I | Secure Boot Image Verification Failure has been cleared as no failure in this round boot. | Informational |
FQXSFPU0025I | The default system settings have been restored. | Informational |
FQXSFPU0038I | A correctable error (Type [arg1]) has been detected by processor [arg2]. | Informational |
FQXSFPU4034I | TPM Firmware recovery is finished, rebooting system to take effect. | Informational |
FQXSFPU4038I | TPM Firmware recovery successful. | Informational |
FQXSFPU4041I | TPM Firmware update is in progress. Please DO NOT power off or reset system. | Informational |
FQXSFPU4042I | TPM Firmware update is finished, rebooting system to take effect. | Informational |
FQXSFPU4044I | The current TPM firmware version could not support TPM version toggling. | Informational |
FQXSFPU4046I | TPM Firmware will be updated from TPM1.2 to TPM2.0. | Informational |
FQXSFPU4047I | TPM Firmware will be updated from TPM2.0 to TPM1.2. | Informational |
FQXSFPU4049I | TPM Firmware update successful. | Informational |
FQXSFPU4059I | User requested to skip freezing lock of AHCI-attached SATA drives. System UEFI accepted the request and will execute priot to OS boot. | Informational |
FQXSFPU4060I | Skipped freezing lock of AHCI-attached SATA drives. | Informational |
FQXSFPU4061I | Restored default locking behavior of AHCI-attached SATA drives. | Informational |
FQXSFPU4070I | Platform secure boot fuse is enabled. | Informational |
FQXSFPU4071I | Platform secure boot fuse is disabled. | Informational |
FQXSFPU4080I | Host Power-On password has been changed. | Informational |
FQXSFPU4081I | Host Power-On password has been cleared. | Informational |
FQXSFPU4082I | Host Admin password has been changed. | Informational |
FQXSFPU4083I | Host Admin password has been cleared. | Informational |
FQXSFPU4084I | Host boot order has been changed. | Informational |
FQXSFPU4085I | Host WOL boot order has been changed. | Informational |
FQXSFSM0007I | The XCC System Event log (SEL) is full. | Informational |
FQXSFSR0002I | [arg1] GPT corruption recovered, DiskGUID: [arg2] | Informational |
FQXSFDD0001G | DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1. | Warning |
FQXSFDD0002M | DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller. | Warning |
FQXSFDD0003I | DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller. | Warning |
FQXSFDD0005M | DRIVER HEALTH PROTOCOL: Disconnect Controller Failed. Requires 'Reboot'. | Warning |
FQXSFDD0006M | DRIVER HEALTH PROTOCOL: Reports Invalid Health Status Driver. | Warning |
FQXSFDD0007G | Security Key Lifecycle Manager (SKLM) IPMI Error. | Warning |
FQXSFIO0013I | The device found at Bus [arg1] Device [arg2] Function [arg3] could not be configured due to resource constraints. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6]. | Warning |
FQXSFIO0021J | PCIe Error Recovery has occurred in physical [arg1] number [arg2]. The [arg3] may not operate correctly. | Warning |
FQXSFIO0022J | PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3] number [arg4]. | Warning |
FQXSFIO0023J | PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3] number [arg4]. | Warning |
FQXSFIO0029G | Correctable CPU link error has been detected on processor [arg1]. | Warning |
FQXSFMA0012L | The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at address [arg3]. [arg4] | Warning |
FQXSFMA0026G | Multi-bit CE occurred on DIMM [arg1], need to restart the system for DIMM Self-healing to attempt post package repair (PPR). | Warning |
FQXSFMA0027G | Multi-bit CE occurred on DIMM [arg1] different rows.[arg2] | Warning |
FQXSFMA0027M | DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7] | Warning |
FQXSFMA0028M | DIMM [arg1] Self-healing, attempt post package repair (PPR) exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4] Bank [arg5] Row [arg6] on Device [arg7]. [arg8] | Warning |
FQXSFMA0047M | SPD CRC checking failed on DIMM [arg1]. [arg2] | Warning |
FQXSFMA0048M | DIMM [arg1] disabled due to PMIC failure during POST, DIMM identifier is [arg2]. | Warning |
FQXSFMA0050G | DRAM PFA threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank [arg3] DRAM [arg4], DIMM identifier is [arg5]. | Warning |
FQXSFMA0057G | Page Retire PFA Threshold limit exceeded on DIMM [arg1] at address [arg2].[arg3] [arg4] | Warning |
FQXSFMA0067G | Errors per row counter threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank [arg3] DRAM [arg4], need to restart the system for DIMM Self-healing to attempt post package repair (PPR), DIMM identifier is [arg5]. | Warning |
FQXSFPU0021G | Hardware physical presence is in asserted state. | Warning |
FQXSFPU0022G | The TPM configuration is not locked. | Warning |
FQXSFPU0023G | Secure Boot Image Verification Failure Warning. | Warning |
FQXSFPU4033F | TPM Firmware recovery is in progress. Please DO NOT power off or reset system. | Warning |
FQXSFPU4035M | TPM Firmware recovery failed. TPM chip may be damaged. | Warning |
FQXSFPU4040M | TPM selftest has failed. | Warning |
FQXSFPU4043G | TPM Firmware update aborted. System is rebooting... | Warning |
FQXSFPU4045G | Physical Presence is not asserted, abort TPM Firmware upgrade. | Warning |
FQXSFPU4050G | Failed to update TPM Firmware. | Warning |
FQXSFPU4051G | Undefined TPM_POLICY found | Warning |
FQXSFPU4052G | TPM_POLICY is not locked | Warning |
FQXSFPU4053G | System TPM_POLICY does not match the planar. | Warning |
FQXSFPU4054G | TPM card logical binding has failed. | Warning |
FQXSFPU4072G | Platform secure boot policy is not defined. | Warning |
FQXSFPU4073G | Platform secure boot fuse is enabled but CPU 1 unfused. | Warning |
FQXSFPU4074G | Platform secure boot fuse is enabled but CPU 2 unfused. | Warning |
FQXSFPU4075G | Platform secure boot fuse is enabled but CPU 1,2 unfused. | Warning |
FQXSFPU4076G | Platform secure boot fuse is disabled but CPU 1 fused. | Warning |
FQXSFPU4077G | Platform secure boot fuse is disabled but CPU 2 fused. | Warning |
FQXSFPU4078G | Platform secure boot fuse is disabled but CPU 1,2 fused. | Warning |
FQXSFSM0002N | Boot Permission denied by Management Module: System Halted. | Warning |
FQXSFSM0003N | Timed Out waiting on boot permission from Management Module: System Halted. | Warning |
FQXSFSM0004M | An XCC communication failure has occurred. | Warning |
FQXSFSR0001M | [arg1] GPT corruption detected, DiskGUID: [arg2] | Warning |
FQXSFSR0003G | The number of boot attempts has been exceeded. No bootable device found. | Warning |
FQXSFTR0001L | An invalid date and time have been detected. | Warning |
FQXSFDD0004M | DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required Controller. | Error |
FQXSFDD0008K | Self-Encrypting Drive (SED) Error: failed to get key. | Error |
FQXSFDD0009K | Self-Encrypting Drive (SED) Error: failed to access drive [arg1]. | Error |
FQXSFDD0010K | Self-Encrypting Drive (SED) Error: failed to unlock drive [arg1]. | Error |
FQXSFDD0011K | Self-Encrypting Drive (SED) Error: failed to set password to drive [arg1]. | Error |
FQXSFDD0012K | SATA Hard Drive Error: [arg1]. | Error |
FQXSFIO0005M | An intra-board UPI failure has been detected on the link between processor [arg1] port [arg2] and processor [arg3] port [arg4]. | Error |
FQXSFIO0010M | An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical [arg6] number is [arg7]. | Error |
FQXSFIO0011M | A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6]. | Error |
FQXSFIO0012M | A PCIe system error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6]. | Error |
FQXSFIO0014J | A bad option ROM checksum was detected for the device found at Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6]. | Error |
FQXSFIO0017M | IFM: Error communicating with the XCC - IFM may not be deployed correctly. | Error |
FQXSFIO0019J | PCIe Resource Conflict. | Error |
FQXSFIO0024J | PCIe Link Training Failure has occurred in physical [arg1] number [arg2]. | Error |
FQXSFIO0030M | Uncorrectable CPU link error has been detected on processor [arg1]. | Error |
FQXSFIO0042N | An uncorrectable USB error (Type [arg1]) is detected on processor [arg2] USB controller [arg3]. | Error |
FQXSFMA0001M | DIMM [arg1] has been disabled due to an error detected during POST. [arg2] | Error |
FQXSFMA0002M | An uncorrectable memory error has been detected on DIMM [arg1] at address [arg2]. [arg3] | Error |
FQXSFMA0008M | DIMM [arg1] has failed the POST memory test. [arg2] | Error |
FQXSFMA0027K | Invalid memory configuration (Unsupported DIMM Population) detected. Please verify memory configuration is valid. | Error |
FQXSFPU0018N | CATERR(IERR) has asserted on processor [arg1]. | Error |
FQXSFPU0019N | An uncorrectable error has been detected on processor [arg1]. | Error |
FQXSFPU0030N | A firmware fault has been detected in the UEFI image. | Error |
FQXSFPU0031N | The number of POST attempts has reached the value configured in F1 setup.The system has booted with default UEFI settings. User specified settings have been preserved and will be used on subsequent boots unless modified before rebooting. | Error |
FQXSFPU0034L | The TPM could not be initialized properly. | Error |
FQXSFPU0063N | CPU [arg1] cores [arg2] disabled. | Error |
FQXSFPU4056M | TPM card is changed, need install back the original TPM card which shipped with the system. | Error |
FQXSFSM0008M | Boot permission timeout detected. | Error |
Give documentation feedback