Technical rules for system fans
Understanding the technical rules for system fans helps you install the correct type and number of fans based on what is configured for your server.
Fan redundancy rules
Supported fan types:
Standard fan 4056 (21000 RPM)
Performance fan 4056 (28000 RPM)
Fan redundancy: N+1 redundancy, one redundant fan rotor
One processor: six hot-swap dual rotor system fans (one redundant fan rotor)
Two processors: eight hot-swap dual rotor system fans (one redundant fan rotor)
Fan selection rules
The following lists the rules for selecting standard or performance fan.
Use | If your server meets any of the following conditions: |
---|---|
Standard or performance fan | TDP <= 165 W |
Performance fan |
|
Standard fans are enough for low-wattage processors while you can still use performance fans for better cooling.
If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still plugged in to AC power, fans 1 and 2 will continue to spin at a much lower speed. This is the system design to provide proper cooling for the OCP 3.0 Ethernet adapter.