Skip to main content

3.5-inch drive bay chassis

Use the parts list in this section to identify each of the components that are available for server models with 3.5-inch front drive bays.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration. Some parts are available only on some models.
Figure 1. Server components (3.5-inch drive bay chassis)
The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

  • F: Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.

  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts (components, such as a filler or bezel) is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

Note
DescriptionTypeDescriptionType
1a ManifoldsF1b 42U/48U in-rack connection hose (return side)F
1c 48U in-rack connection hose (supply side)F1d 42U in-rack connection hose (supply side)F
1e 42U in-row hose kitF1f Bleeder kitF
2a Cold plate coverC2b Processor Neptune Core ModuleF
2c 1FH bracket for Neptune Core ModuleC2d Hose holderC
2e 3FH riser cage for Neptune Core ModuleC3 Riser cagesC
4 Riser cardsT1/F5 GPU air baffle fillersC
6 GPU air baffleT17 Standard air baffle fillerC
8 Standard air baffleT19 Heat sinksF
10 RAID flash power module (supercap)T111 3FH M.2 riser cageC
12 Rear M.2 backplaneT213 1FH M.2 riser cageC
14 M.2 heat sinkF15 M.2 driveT1
16 M.2 thermal padF17 M.2 interposerT2
18 M.2 drive trayC19 2.5" driveT1
20 2.5" drive fillerC21 Rack latchesT1
22 ChassisF23 External diagnostics handsetT1
24 Security bezelT125 3.5" driveT1
26 3.5" drive filler (1-bay)C27 3.5" drive filler (4-bay)C
28 4 x 3.5" SAS/SATA rear backplaneT129 12 x 3.5" SAS/SATA front backplaneT2
30 12 x 3.5" AnyBay front backplaneT231 4 x 2.5" AnyBay middle/rear backplaneF
32 Middle bracketsT133 FanT1
34 Fan cageC35 2U cable wallC
36 Memory moduleT137 Processor and heat sink module fillerF
38 CMOS battery (CR2032)C39 PCIe adapterT1
40 OCP moduleT141 Top coverT1
42 Power supply unitT143 4 x 2.5" rear drive cageC
44 4 x 3.5" rear drive cageC45 M.2 RAID SATA/NVMe 2-bay backplaneT2
46 M.2 retainerT247 M.2 non-RAID NVMe 2-bay backplaneT2
48 ProcessorF49 Processor socket coverC
50 MicroSD cardT151 System I/O board (DC-SCM)F
52 Processor boardF53 USB I/O boardT1
54 8 x 2.5" middle drive cageC