Parts list

Identify each of the components that is available for your server with the parts list.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration. Some parts are available only on some models.
Figure 1. Server components

The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

  • F:Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.

  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts (components, such as a filler or bezel) is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

Table 1. Parts list
DescriptionTypeDescriptionType
1 Top coverT12 Rear wall bracketsT1
3 Power supply unitT14 7mm drive bay fillerC
5 7mm driveT16 Rear 4 x 3.5-inch drive cageT1
7 OCP moduleT18 Rear 2 x 3.5-inch drive cageT1
9 Rear 4 x 2.5-inch drive cageT110 RAID flash power moduleT1
11 RAID flash power module holderT112 Front 8 x 2.5-inch drive backplaneT1
13 Middle/Rear 4 x 2.5-inch drive backplaneT114 Rear 2 x 3.5-inch drive backplaneT1
15 Rear 8 x 2.5-inch drive backplaneT116 Front 24 x 2.5-inch expander backplaneT1
17 Rear 4 x 3.5-inch drive backplaneT118
Front 12 x 3.5-inch drive backplane:
  • 12 x 3.5-inch SAS/SATA drive backplane

  • 12 x 3.5-inch AnyBay drive backplane

  • 12 x 3.5-inch expander backplane

T1
19 Front 8 x 3.5-inch drive backplaneT120 System fanT1
21 System fan cageT122 Intrusion switchT1
23 CFF RAID adapter/expanderT224 Right rack latch with front I/O moduleT1
25 Standard right rack latchT126 Left rack latch with VGA and external diagnostics portsT1
27 Left rack latch with external diagnostics portT128 Left rack latch with VGA portT1
29 Standard left rack latchT130 Front I/O module with integrated diagnostics panelT1
31 Integrated diagnostics panelT132 Front I/O module with front operator panelT1
33 3.5-inch driveT134 2.5-inch driveT1
35 3.5-inch drive fillers (1-bay)C36 3.5-inch drive fillers (4-bay)C
37 Security bezelC38 External diagnostics handsetT1
39 2.5-inch drive fillers (1-bay, 4-bay, or 8-bay)C40 Fan boardF
41 Processor boardF42 System I/O boardF
43 Firmware and RoT security moduleF44 PIBF
45 MicroSD cardT146 ProcessorF
47 Memory moduleT148 CMOS battery (CR2032)C
49 T-shape performance heat sinkF50 2U standard heat sinkF
51 M.2 drive backplaneT152 M.2 driveT1
53 M.2 retainer clipT154 GPU air baffle fillerC
55 Add-on air baffle (for GPU air baffle)T156 Standard air baffle fillerT1
57 Hose holderC58 1FH riser cage for DWCMT1
59 3FH riser cage for DWCMT160 Cold plate coverC
61 Direct water cooling moduleF62 Middle 4 x 3.5-inch drive cageT1
63 Middle 8 x 2.5-inch drive cageT164 GPU air baffleT1
65 Standard air baffleC66 Top cover mylar noteT1
67 Riser card (LP)T268 4LP riser 3/4 cageT1
69 7mm drive cage (2FH + 7mm)T170 7mm drive cage (1U)T1
71 7mm drive backplanesT272 Riser 3 cageT1
73 Riser 1 or riser 2 cageT174 1U riser cageT1
75 PCIe adapterT176 Serial port moduleT1
77 1 FH riserT278 Riser 1 or riser 2 cardT1
79 Riser 3 cardT280 3.5-inch drive bay chassisF
81 2.5-inch drive bay chassisF82 Front OCP interposer cardT1
83 Front adapter cageT184 Riser 5 cardT2
85 Rear OCP interposer cardT186 Management NIC adapterT1
Note
The top cover mylar is needed only for configurations with a front retimer card. For details, see Install the top cover.