16 x 2.5-inch front drive bays (8AnyBay+8NVMe)
This section provides cable routing information for the server model with 16 x 2.5-inch front drive bays (8AnyBay+8NVMe).
Note
The AnyBay backplane (BP2) is used as pure NVMe backplane.
| Configuration | Storage controller | |
| Qty. | Type | |
| Config. 1 | 2 | NVMe switch +SFF 8i RAID/HBA |
| Config. 3 | 2 | NVMe switch +SFF 16i RAID/HBA |
Configuration 1 – 2:
BP 1 + BP 2: 8 x 2.5'' AnyBay BP + 8 x 2.5'' NVMe BP
| Config. | Front BP | System board | Storage controller | ||
| NVMe switch | SFF 8i RAID/HBA | SFF 16i RAID/HBA | |||
| 1 | BP 1: NVMe 0–1 | PCIe 1, PCIe 2 | |||
| BP 1: NVMe 2–3 | PCIe 3 | ||||
| BP 1: NVMe 4–5, NVMe 6–7 | C 0, C 1 | ||||
| BP 1: SAS | Gen 4: C 0 Gen3: C 0, C 1 | ||||
| BP 2: NVMe 0–1 | PCIe 4, PCIe 5 | ||||
| BP 2: NVMe 2–3 | PCIe 6 | ||||
| BP 2: NVMe 4–5 | PCIe 7 | ||||
| BP 2: NVMe 6–7 | PCIe 8 | ||||
| 2 | BP 1: NVMe 0–1 | PCIe 1, PCIe 2 | |||
| BP 1: NVMe 2–3 | PCIe 3 | ||||
| BP 1: NVMe 4–5, NVMe 6–7 | C 0, C 1 | ||||
| BP 1: SAS | Gen 4: C 0 Gen3: C 0, C 1 | ||||
| BP 2: NVMe 0–1 | PCIe 4, PCIe 5 | ||||
| BP 2: NVMe 2–3 | PCIe 6 | ||||
| BP 2: NVMe 4–5 | PCIe 7 | ||||
| BP 2: NVMe 6–7 | PCIe 8 | ||||
Example
Figure 1. Configuration 2


Give documentation feedback