FQXSPPU2007I : The System [ComputerSystemElementName] has detected a POST Error deassertion.
The System [ComputerSystemElementName] has detected a POST Error deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity
Info
Alert Category
Critical - CPU
Serviceable
Yes
SNMP Trap ID
40
Automatically Notify Support
No
User Action
Complete the following steps:
- If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the correct population sequence.
- RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot to F1 setup and enable the DIMM. Reboot the system.
- If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
- If the problem persists, collect Service Data logs.
- Contact Lenovo Support.
Give documentation feedback