FQXSPPW0003G : Failure predicted on [PowerSupplyElementName].
Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is predicted.
Severity
Warning
Alert Category
Warning - Power
Serviceable
Yes
SNMP Trap ID
164
Automatically Notify Support
No
User Action
Complete the following steps:
- Check the event log of system management module and XClarity Controller for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place,clean, and correctly installed.
- Make sure that the room temperature is within operating specifications.
- If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.