Skip to main content

Front operator panel LEDs

This section contains information about the front operator panel LEDs.

1 Power button with power status LED (green)

You can press the power button to power on the server when you finish setting up the server. You also can hold the power button for several seconds to power off the server if you cannot shut down the server from the operating system. The states of the power LED are as follows:

StatusColorDescription
OffNoneNo power supply is properly installed, or the LED itself has failed.
Flashing rapidly (four times per second)GreenThe server is turned off and is not ready to be turned on. The power button is disabled. This will last approximately 5 to 10 seconds.
Flashing slowly (once per second)GreenThe server is turned off and is ready to be turned on. You can press the power button to turn on the server.
LitGreenThe server is turned on.

2 Network activity LED (green)

The network activity LED helps you identify the network connectivity and activity.

StatusColorDescription
OnGreenThe server is connected to a network.
BlinkingGreenThe network is connected and active.
OffNoneThe server is disconnected from the network.

3 System ID button with system ID LED (blue)

Use this system ID button and the blue system ID LED to visually locate the server. Each time you press the system ID button, the state of the system ID LED changes. The LED can be changed to on, blinking, or off. You can also use the Lenovo XClarity Controller or a remote management program to change the state of the system ID LED to assist in visually locating the server among other servers.

4 System Error LED (yellow)

The system error LED helps you to determine if there are any system errors.

StatusColorDescriptionAction
OnYellow
An error has been detected on the server. Causes might include one or more of the following errors:
  • The temperature of the server reached the non-critical temperature threshold.

  • The voltage of the server reached the non-critical voltage threshold.

  • A fan has been detected to be running at low speed.

  • The power supply has a critical error.

  • The power supply is not connected to the power.

Check the Event log to determine the exact cause of the error.

OffNoneThe server is off or the server is on and is working correctly.None.