Use this information to install a heat sink retention module.
Read the safety information in Safety and Installation guidelines.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices, and disconnect the power cords and all external cables.
To install a heat sink retention module, complete the following steps.
- Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Do not allow the server to fall over.
- Unlock and remove the left-side cover (see Removing the left-side cover).
- Remove the air baffle (see Removing the air baffle).
- Align the retention module with the holes on the system board.
- Use a screwdriver to install the four screws.
Figure 1. Heat sink retention module installation![Heat sink retention module installation](ct1ab132.jpg)
- Install the heat sink (see Installing a microprocessor and heat sink).
Make sure that you install each heat sink with its paired microprocessor.
- Install the air baffle (see Installing the air baffle).
- Install and lock the left-side cover (see Installing the left-side cover).
If you have replaced a server component or installed an optional device in the server, you need to reconnect the power cords and all external cables, and turn on the server and peripheral devices.