806f0513-2582xxxx : A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
May also be shown as 806f05132582xxxx or 0x806f05132582xxxx
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
1. Check the PCI LED. 2. Reseat the affected adapters and riser card. 3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code. 4. Make sure that the adapter is supported. For a list of supported optional devices, see http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/. 5. Remove both adapters. 6. Replace the PCIe adapters. 7. Replace the riser cards.