816f000d-0405xxxx : The Drive [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 5)
The Drive [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 5)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0405xxxx or 0x816f000d0405xxxx
Severity
Error
Alert Category
Critical - Hard Disk drive
Serviceable
Yes
SNMP Trap ID
5
Automatically Notify Support
No
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive. 2. Replace the hard disk drive. 3. Make sure that the disk firmware and RAID controller firmware is at the latest level. 4. Check the SAS cable.
Give documentation feedback