FQXSFPU0030N : A firmware fault has been detected in the UEFI image.
A firmware fault has been detected in the UEFI image.
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
Complete the following steps: \n1) Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error.\n2) Reflash UEFI image.\n3) Undo recent system changes (settings or devices added). Verify that the system boots. Then, re-install options one at a time to locate the problem.\n4) If problem persists, save customer's UEFI configurations, then remove and re-install CMOS battery for 30 seconds to clear CMOS contents. If it boots successfully, then restore system settings.\n5) If the problem persists, collect Service Data logs.\n6) Contact Lenovo Support.