Install the EIA brackets

Follow instructions in this section to install the EIA brackets.

About this task

Attention
Note
Depending on the configuration, the EIA brackets might look slightly different from the illustration in this section.

Procedure

Secure each of the EIA brackets to the chassis with four or six screws. Make sure to align the two brackets to the same numbers (1 to 6) or the “MAX” mark on both sides of the chassis.
Note
The EIA brackets are designed as adjustable. To ensure sufficient space for security bezel or the external cables at front of the server, adjust the depth of EIA brackets according to the operation environment.
Figure 1. Depth mark for EIA brackets

Figure 2. EIA bracket regular depth 1 to 6: six screws

Figure 3. EIA bracket maximal depth for security bezel: four screws

After this task is completed

If the server was installed in a rack, reinstall the server into the rack. See Install the server to the rack.