Skip to main content

FQXSPCA0007J : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has asserted.

Severity

Warning

Alert Category

Warning - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0490

SNMP Trap ID

12

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the Chassis Management Module or XCC event log for any fan- or cooling-related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.