Skip to main content

8/16/24 x 2.5" AnyBay (tri-mode)

This topic provides cable routing information for the 8 x 2.5"/16 x 2.5"/24 x 2.5" AnyBay (tri-mode) configuration.

The configuration numbers in the table below are for descriptive purposes only.
BP config.Storage controllerConfig. No.
8 x 2.5" AnyBay (BP1)1 x SFF 8i/16i (tri-mode)1
1 x CFF 16i (tri-mode)2
16 x 2.5" AnyBay (BP1 + BP2)2 x SFF 8i (tri-mode)3
1 x SFF 16i (tri-mode)4
1 x CFF 16i (tri-mode)5
24 x 2.5" AnyBay (BP1 + BP2 + BP3)3 x SFF 8i (tri-mode)6
SFF 16i + 8i (tri-mode)7
SFF 8i + CFF 16i (tri-mode)8

Cable routing to SFF 8i/16i adapter (config. 1/3/4/6/7)

Note
  • The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.

  • Cable 3 is needed only in the 3 x SFF 8i or SFF 16i + 8i configuration.

Figure 1. Cable routing to SFF 8i/16i adapter

FromToCable length
1 BP1: SAS1 8i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

1 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
2 BP2: SAS2 8i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

2
  • Gen 4: C1

  • Gen 3: C2C3

900 mm
3 BP3: SAS3 8i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

3 8i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm

Cable routing to CFF 16i adapter (config. 2/5/8)

Figure 2. Cable routing when two processors are installed

Figure 3. Cable routing when one processor is installed

2P: two processors; 1P: one processor; PB: processor board
From (CFF 16i adapter)ToCable length
2P1P
1 POWER

1 PB: RAID PWR

1a PB: RAID PWR
  • 2P: 210 mm

  • 1P: 300/800 mm

1b PB: PWR 14
2a C02 BP1: SAS2 BP1: SAS140/140 mm
2b C1
3a C23 BP2: SAS3 BP2: SAS140/140 mm
3b C3
4 MB (CFF INPUT)4 PB: PCIe 44 PB: PCIe 4450 mm

Cable routing to SFF 8i adapter (config. 8)

Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 4. Cable routing to SFF 8i adapter

FromToCable length
1 BP3: SAS1 8i adapter: C0900 mm