8 x 2.5" AnyBay + 8 x 2.5" NVMe
This topic provides cable routing information for the 8 x 2.5" AnyBay + 8 x 2.5" NVMe configuration.
The configuration numbers in the table below are for descriptive purposes only.
BP config. | Storage controller | Config. No. |
---|---|---|
8 x 2.5" AnyBay + 8 x 2.5" NVMe (BP1 + BP2) | 1 x SFF 8i/16i | 1 |
1 x CFF 16i | 2 |
NVMe cable routing (config. 1/2)
Figure 1. Cable routing when two processors are installed ![]() | Figure 2. Cable routing when one processor is installed ![]() |
2P: two processors; 1P: one processor
From | To (processor board) | Cable length | |
---|---|---|---|
2P | 1P | ||
1 BP1: NVMe 0-1 | 1 PCIe 8 | 1 PCIe 11A |
|
2 BP1: NVMe 2-3 | 2 PCIe 7 | 2 PCIe 11B |
|
3 BP1: NVMe 4-5 | 3 PCIe 6 | 3 PCIe 4 |
|
4 BP1: NVMe 6-7 | 4 PCIe 5 | 4 PCIe 3 |
|
5 BP2: NVMe 0-1 | 5 PCIe 4 | 5 PCIe 2 |
|
6 BP2: NVMe 2-3 | 6 PCIe 3 | 6 PCIe 1 |
|
7 BP2: NVMe 4-5 | 7 PCIe 2 | 7 PCIe 9B |
|
8 BP2: NVMe 6-7 | 8 PCIe 1 | 8 PCIe 9A |
|
Cable routing to SFF 8i/16i adapter (config. 1)
Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 3. Cable routing to SFF 8i/16i adapter


From | To | Cable length |
---|---|---|
1 BP1: SAS | 1 8i/16i adapter:
| 900 mm |
Cable routing to CFF 16i adapter (config. 2)
Figure 4. Cable routing when two processors are installed ![]() | Figure 5. Cable routing when one processor is installed ![]() |
PB: processor board; 2P: two processors; 1P: one processor
From (CFF 16i adapter) | To | Cable length | |
---|---|---|---|
2P | 1P | ||
1 POWER | 1 PB: RAID PWR | 1a PB: RAID PWR |
|
1b PB: PWR 14 | |||
2a C0 | 2 BP1: SAS | 2 BP1: SAS |
|
2b C1 | |||
3 MB (CFF INPUT) | 3 PB: PCIe 14 | 3 PB: PCIe 10 |
|
Give documentation feedback