Switch blocks
Switch blocks are located on the system board.
If there is a clear protective sticker on the top of the switch blocks, you must remove and discard it to access the switches.
Any system-board switch or jumper block that is not shown in the illustrations in this document is reserved
SW1 (PCH/ME switch block)
Table 1 describes the functions of the switch block.
Switch position number | Default position | Function | Description |
---|---|---|---|
1 | Off | Clear CMOS | Toggle to ON to clear the real time clock (RTC) registry. |
- Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. Review the information in Safety Information page, Installation Guidelines, Handling static-sensitive devices, and Power off the server.
SW6 (system switch block 1)
Table 2 describes the functions of the switch block.
Switch position number | Default position | Function | Description |
---|---|---|---|
2 | Off | Force XCC update | Toggle to ON to force the Lenovo Xclarity Controller to update to the latest version. |
- Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. Review the information in Safety Information page, Installation Guidelines, Handling static-sensitive devices, and Power off the server.
SW7 (system switch block 2)
Table 3 describes the functions of the switch block.
Switch position number | Default position | Function | Description |
---|---|---|---|
2 | Off | Override power-on password | Toggle to ON to override the power-on password. |
4 | Off | Force XCC reset | Toggle to ON to reset the Lenovo XClarity Controller. |
- Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. Review the information in Safety Information page, Installation Guidelines, Handling static-sensitive devices, and Power off the server.
SW11 (FPGA switch block)
Table 4 describes the functions of the switch block.
Switch position number | Default position | Function | Description |
---|---|---|---|
1 | Off | TPM physical presence | Toggle to ON to assert physical presence. |
- Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. Review the information in Safety Information page, Installation Guidelines, Handling static-sensitive devices, and Power off the server.