Install the optical drive cage

Follow instructions in this section to install the optical drive cage.

S002
disconnect all power
CAUTION
The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
S006
Laser hazard
CAUTION
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following:
  • Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
  • Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.
About this task
Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Touch the static-protective package that contains the component to any unpainted metal surface on the server; then, remove it from the package and place it on a static-protective surface.

Procedure

  1. Make sure the cage bar is installed in the chassis. To install the cage bar, see Install the server cover.
  2. (Optional) Install the EMI shield included in the component packaging to the chassis.
    Note
    Installing the EMI shield is required when the original shield slot on the chassis is vacant.
    1. Insert the tabs on the left end of the EMI shield into the shield slot on the chassis.
    2. Push the EMI shield into the chassis until it snaps into place.
      Figure 1. Installing the EMI shield
      Installing the EMI shield
  3. Make sure there is no optical drive installed on the optical drive cage. Then, Install the optical drive cage to the bay 2 drive cage.
    1. Align the four hooks on the optical drive cage with the corresponding hooks on the bay 2 drive cage; then, lower the optical drive cage onto the bay 2 drive cage, and slide the optical drive cage forward until it secures into place.
      Note
      Make sure the four hooks on both drive cages are fully engaged.
    2. Fasten the screw to secure the two drive cages together.
      Figure 2. Installing the optical drive cage to the bay 2 drive cage
      Installing the optical drive cage to the bay 2 drive cage
  4. If applicable, install the 3.5-inch drive to the bay 2 drive cage. See Install a simple-swap drive (bay 2).
  5. Install the ODD+bay 2 drive cage assembly.
    1. Align the four pins on the sides of the optical drive cage with the four slots on the chassis and cage bar; then, lower the drive cage assembly into the chassis.
    2. Ensure that the drive cage assembly is seated correctly; then, rotate the handle on the optical drive cage toward the front of the chassis to secure the drive cage assembly into place.
      Figure 3. Installing the ODD+bay 2 drive cage assembly
      Installing the ODD+bay 2 drive cage assembly
Procedure
  1. If applicable, install the optical drive. See Install an optical drive.

  2. Connect the signal and power cables to the 3.5-inch drive and optical drive. See Internal cable routing.

  3. Complete the parts replacement. See Complete the parts replacement.