Server models with eight 3.5-inch hot-swap drives
Use this section to understand the cable routing for server models with eight 3.5-inch hot-swap SAS/SATA drives.
Server model: eight 3.5-inch SAS/SATA drives, one 8i RAID adapter
Note
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Figure 1. Cable routing for server models with eight 3.5-inch SAS/SATA drives and one 8i RAID adapter
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1* | SAS connector on backplane 1 | HBA/RAID adapter:
|
2 SAS signal cable for backplane 2* | SAS connector on backplane 2 | HBA/RAID adapter:
|
3 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
4 Power cable for backplane 2 | Power connector on backplane 2 | Backplane 2 power connector on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem ST550 3.5" SAS/SATA 4-Bay X40 RAID Cable Kit). Cable 1 and cable 2 are combined into one cable for Gen 4.