Server models with sixteen 2.5-inch hot-swap drives
Use this section to understand the cable routing for server models with sixteen 2.5-inch hot-swap drives.
Server model: sixteen 2.5-inch SAS/SATA drives, two 8i RAID adapters
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1* | SAS 0 and SAS 1 connectors on backplane 1 | HBA/RAID adapter:
|
2 SAS signal cable for backplane 2* | SAS 0 and SAS 1 connectors on backplane 2 | HBA/RAID adapter:
|
3 Power cable for backplane 2 | Power connector on backplane 2 | Backplane 2 power connector on the system board |
4 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
Server model: sixteen 2.5-inch SAS/SATA drives, one 24i RAID adapter
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1 | SAS 0 and SAS 1 connectors on backplane 1 | C0 and C1 connectors on the 24i RAID adapter |
2 SAS signal cable for backplane 2 | SAS 0 and SAS 1 connectors on backplane 2 | C2 and C3 connectors on the 24i RAID adapter |
3 Power cable for backplane 2 | Power connector on backplane 2 | Backplane 2 power connector on the system board |
4 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
Server model: sixteen 2.5-inch SAS/SATA drives, one 32i RAID adapter
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1* | SAS 0 and SAS 1 connectors on backplane 1 | C0 connector on the 32i RAID adapter (Gen 4) |
2 SAS signal cable for backplane 2* | SAS 0 and SAS 1 connectors on backplane 2 | C1 connector on the 32i RAID adapter (Gen 4) |
3 Power cable for backplane 2 | Power connector on backplane 2 | Backplane 2 power connector on the system board |
4 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
Server model: twelve 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, one 16i RAID adapter, one NVMe adapter
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1* | SAS 0 and SAS 1 connectors on backplane 1 | HBA/RAID adapter:
|
2 SAS signal cable for backplane 2* | SAS 0 and SAS 1 connectors on backplane 2 | HBA/RAID adapter:
|
3 NVMe signal cable for backplane 1 | NVMe 0, NVMe 1, and NVMe 2, and NVMe 3 connectors on backplane 1 | C0, C1, C2, and C3 connectors on the NVMe adapter |
4 Power cable for backplane 2 | Power connector on backplane 2 | Backplane 2 power connector on the system board |
5 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
Server model: twelve 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, two 8i RAID adapters, one NVMe adapter
Ensure that all cables are routed through the correct cable clips.
Broken lines indicate the hidden parts.
Cable | From | To |
---|---|---|
1 SAS signal cable for backplane 1* | SAS 0 and SAS 1 connectors on backplane 1 | HBA/RAID adapter:
|
2 NVMe signal cable for backplane 1 | NVMe 0, NVMe 1, and NVMe 2, and NVMe 3 connectors on backplane 1 | C0, C1, C2, and C3 connectors on the NVMe adapter |
3 Power cable for backplane 1 | Power connector on backplane 1 | Backplane 1 power connector on the system board |
4 SAS signal cable for backplane 2* | SAS 0 and SAS 1 connectors on backplane 2 | HBA/RAID adapter:
|