Skip to main content

FQXSPMA0012M : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

Severity​

Error

Alert Category​

Critical - Temperature

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0146

SNMP Trap ID​

0

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check the event log of XClarity Controller (XCC) for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.