FQXSPFW0002N : The System [ComputerSystemElementName] encountered a firmware hang.
The System [ComputerSystemElementName] encountered a firmware hang.
This message is for the use case when an implementation has detected a System Firmware Hang.
Severity
Error
Alert Category
System - Boot failure
Serviceable
Yes
SNMP Trap ID
25
Automatically Notify Support
No
User Action
Complete the following steps:
- Original UEFI settings are still present. If customer desires to continue using the original settings, select Save Settings.
- If User did not intentionally trigger the reboots, check logs for probable cause. For example, if there is a battery fault event, follow the steps to resolve that event.
- Undo recent system changes (settings or devices added). Verify that the system boots. Then, re-install options one at a time to locate the problem.
- Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
- Remove and re-install CMOS battery on system board for 60 seconds to clear CMOS contents. If it boots successfully, then restore system settings.
- If problem persists, collect Service Data log.
- Contact Lenovo Support.
Give documentation feedback