FQXSPPW0047M : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
- If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system board.
- If the specified sensor is Planar 12V, ensure the PDB board is installed correctly and check the XClarity Controller event log for power supply related issues, and resolve those issues.
- If the problem persists, (Trained technician only) replace the PDB board or system board.