FQXSPPW0035M : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
- If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system board.
- If the specified sensor is Planar 12V, ensure the PDB board is installed correctly and check the XClarity Controller event log for power supply related issues, and resolve those issues.
- If the problem persists, (Trained technician only) replace the PDB board or system board.
Give documentation feedback