FQXSPMA0002N : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
Severity
Error
Alert Category
Critical - Memory
Serviceable
Yes
SNMP Trap ID
41
Automatically Notify Support
No
User Action
Complete the following steps:
- If the DIMM configuration was changed prior to this failure, verify that the DIMMs are installed in the correct population sequence.
- Reseat the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot to F1 setup and enable the DIMM. Reboot the system.
- If the DIMMs have been upgraded just prior to the issue, update UEFI to the latest version.
- If the problem persists, collect Service Data logs.
- Contact Lenovo Support.