1 x SAS/SATA backplane
This section lists the required components for server models with 1 x SAS/SATA 2.5-inch hot-swap backplane.
Note
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.
Y-cables are shown as individual cables in the illustrations for each backplane.
Connect cables prioritizing Gen 4 RAID adapters.
For more information on the cables that are used, see Backplane cable list.
This configuration contains the following combinations:
Onboard SATA
SAS/SATA cable routing | ||
---|---|---|
Figure 1. SAS/SATA cable routing to system board | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
1 x 8i RAID/HBA
SAS/SATA cable routing | ||
---|---|---|
Figure 2. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
1 x 16i RAID/HBA
SAS/SATA cable routing | ||
---|---|---|
Figure 3. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
1 x 24i RAID/HBA
SAS/SATA cable routing | ||
---|---|---|
Figure 4. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
1 x 32i RAID/HBA
SAS/SATA cable routing | ||
---|---|---|
Figure 5. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i G4: C0 | 32i G4: SlimSAS x8 to SlimSAS x8 (720 mm) |
1 x CFF RAID/HBA
SAS/SATA cable routing | ||
---|---|---|
Figure 6. SAS/SATA cable routing to CFF RAID/HBA adapter | ||
From | To | Cable |
1 BP1: SAS/SATA | CFF RAID/HBA: C0, C1 | SlimSAS x4*2 to SlimSAS x8 (260 mm/260 mm) |
Give documentation feedback