2 x SAS/SATA + 1 x AnyBay backplane
This section lists the required components for server models with 2 x SAS/SATA + 1 x AnyBay 2.5-inch hot-swap backplane.
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.
Y-cables are shown as individual cables in the illustrations for each backplane.
Connect cables prioritizing Gen 4 RAID adapters.
For more information on the cables that are used, see Backplane cable list.
Onboard NVMe/SATA + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 1. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 2. SAS/SATA cable routing to system board and top PCIe zone Figure 3. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe/SATA + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 4. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 5. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe/SATA + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 6. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 7. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
3 BP3: SAS/SATA | 24i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (930 mm) |
Onboard NVMe + 3 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 8. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 9. SAS/SATA cable routing to top PCIe zone Figure 10. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 11. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 12. SAS/SATA cable routing to top PCIe zone Figure 13. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x 8i RAID/HBA + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 14. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 15. SAS/SATA cable routing to top PCIe zone Figure 16. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
2 BP2: SAS/SATA | 24i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x 32i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 17. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 18. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i G4: C0 | SlimSAS x8 to SlimSAS x8 (720 mm) |
2 BP2: SAS/SATA | 32i G4: C1 | SlimSAS x8 to SlimSAS x8 (720 mm) |
3 BP3: SAS/SATA | 32i G4: C2 | SlimSAS x8 to SlimSAS x8 (720 mm) |
Onboard SATA + 2 x retimers + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 19. NVMe cable routing to top PCIe zone Figure 20. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 21. SAS/SATA cable routing to system board and top PCIe zone Figure 22. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard SATA + 2 x retimers + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 23. NVMe cable routing to top PCIe zone Figure 24. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 25. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard SATA + 2 x retimers + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 26. NVMe cable routing to top PCIe zone Figure 27. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 28. SAS/SATA cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
3 BP3: SAS/SATA | 24i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (930 mm) |
Onboard SATA + 2 x retimers + 1 x CFF RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 29. NVMe cable routing to top PCIe zone Figure 30. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 31. SAS/SATA cable routing to system board and CFF RAID/HBA adapter | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA | CFF RAID/HBA: C0, C1 | SlimSAS x4*2 to SlimSAS x8 (260 mm/260 mm) |
3 BP3: SAS/SATA | CFF RAID/HBA: C2, C3 | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 x retimers + 3 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 32. NVMe cable routing to top PCIe zone Figure 33. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 34. SAS/SATA cable routing to top PCIe zone Figure 35. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
2 x retimers + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 36. NVMe cable routing to top PCIe zone Figure 37. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 38. SAS/SATA cable routing to top PCIe zone Figure 39. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
2 x retimers + 1 x 8i RAID/HBA + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 40. NVMe cable routing to top PCIe zone Figure 41. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 42. SAS/SATA cable routing to top PCIe zone Figure 43. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
2 BP2: SAS/SATA | 16i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
3 BP3: SAS/SATA |
|
|
2 x retimers + 1 x 32i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 44. NVMe cable routing to top PCIe zone Figure 45. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 46. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i G4: C0 | SlimSAS x8 to SlimSAS x8 (720 mm) |
2 BP2: SAS/SATA | 32i G4: C1 | SlimSAS x8 to SlimSAS x8 (720 mm) |
3 BP3: SAS/SATA | 32i G4: C2 | SlimSAS x8 to SlimSAS x8 (720 mm) |