Skip to main content

2 x SAS/SATA + 1 x AnyBay backplane

This section lists the required components for server models with 2 x SAS/SATA + 1 x AnyBay 2.5-inch hot-swap backplane.

Note
  • Connections between connectors; 11, 22, 33, ... nn

  • When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.

  • Y-cables are shown as individual cables in the illustrations for each backplane.

  • Connect cables prioritizing Gen 4 RAID adapters.

  • For more information on the cables that are used, see Backplane cable list.

Onboard NVMe/SATA + 2 x 8i RAID/HBA

NVMe cable routing
Figure 1. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 2. SAS/SATA cable routing to system board and top PCIe zone
SAS/SATA cable routing to system board and top PCIe zone
Figure 3. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard NVMe/SATA + 1 x 16i RAID/HBA

NVMe cable routing
Figure 4. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Figure 5. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard NVMe/SATA + 1 x 24i RAID/HBA

NVMe cable routing
Figure 6. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Figure 7. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
3 BP3: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x8 (930 mm)

Onboard NVMe + 3 x 8i RAID/HBA

NVMe cable routing
Figure 8. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 9. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 10. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 BP2: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard NVMe + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA

NVMe cable routing
Figure 11. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 12. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 13. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 BP2: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard NVMe + 1 x 8i RAID/HBA + 1 x 24i RAID/HBA

NVMe cable routing
Figure 14. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 15. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 16. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
2 BP2: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard NVMe + 1 x 32i RAID/HBA

NVMe cable routing
Figure 17. NVMe cable routing to system board
NVMe cable routing to system board
FromToCable
1 BP1: NVMe 0-1PCIe 1 (onboard)SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm)
2 BP1: NVMe 2-3PCIe 2 (onboard)
3 BP1: NVMe 4-5PCIe 3 (onboard)SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm)
4 BP1: NVMe 6-7PCIe 4 (onboard)
SAS/SATA cable routing
Figure 18. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA32i G4: C0SlimSAS x8 to SlimSAS x8 (720 mm)
2 BP2: SAS/SATA32i G4: C1SlimSAS x8 to SlimSAS x8 (720 mm)
3 BP3: SAS/SATA32i G4: C2SlimSAS x8 to SlimSAS x8 (720 mm)

Onboard SATA + 2 x retimers + 2 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 19. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 20. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 21. SAS/SATA cable routing to system board and top PCIe zone
SAS/SATA cable routing to system board and top PCIe zone
Figure 22. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard SATA + 2 x retimers + 1 x 16i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 23. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 24. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Figure 25. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

Onboard SATA + 2 x retimers + 1 x 24i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 26. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 27. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Figure 28. SAS/SATA cable routing to system board and bottom PCIe zone
SAS/SATA cable routing to system board and bottom PCIe zone
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
3 BP3: SAS/SATA24i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x8 (930 mm)

Onboard SATA + 2 x retimers + 1 x CFF RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 29. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 30. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Figure 31. SAS/SATA cable routing to system board and CFF RAID/HBA adapter
SAS/SATA cable routing to system board and CFF RAID/HBA adapter
FromToCable
1 BP1: SAS/SATASATA 0-3, 4-7 (onboard)SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)
2 BP2: SAS/SATACFF RAID/HBA: C0, C1SlimSAS x4*2 to SlimSAS x8 (260 mm/260 mm)
3 BP3: SAS/SATACFF RAID/HBA: C2, C3SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm)

2 x retimers + 3 x 8i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 32. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 33. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 34. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 35. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 BP2: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 x retimers + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 36. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 37. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 38. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 39. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA
  • 16i G4: C0

  • 16i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 BP2: SAS/SATA
  • 16i G4: C1

  • 16i G3: C2, C3

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 x retimers + 1 x 8i RAID/HBA + 1 x 24i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 40. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 41. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 42. SAS/SATA cable routing to top PCIe zone
SAS/SATA cable routing to top PCIe zone
Figure 43. SAS/SATA cable routing to bottom PCIe zone
SAS/SATA cable routing to bottom PCIe zone
FromToCable
1 BP1: SAS/SATA24i G3: C0, C1Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
2 BP2: SAS/SATA16i G3: C2, C3Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)
3 BP3: SAS/SATA
  • 8i G4: C0

  • 8i G3: C0, C1

  • Gen 4: SlimSAS x8 to SlimSAS x8 (720 mm)

  • Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm)

2 x retimers + 1 x 32i RAID/HBA

NVMe cable routing
Note
Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone.
Figure 44. NVMe cable routing to top PCIe zone
NVMe cable routing to top PCIe zone
Figure 45. NVMe cable routing to bottom PCIe zone
NVMe cable routing to bottom PCIe zone
FromToCable
1 BP1: NVMe 0-1Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
2 BP1: NVMe 2-3Retimer: C1
3 BP1: NVMe 4-5Retimer: C0SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm)
4 BP1: NVMe 6-7Retimer: C1
SAS/SATA cable routing
Figure 46. SAS/SATA cable routing to PCIe slot 9
SAS/SATA cable routing to PCIe slot 9
FromToCable
1 BP1: SAS/SATA32i G4: C0SlimSAS x8 to SlimSAS x8 (720 mm)
2 BP2: SAS/SATA32i G4: C1SlimSAS x8 to SlimSAS x8 (720 mm)
3 BP3: SAS/SATA32i G4: C2SlimSAS x8 to SlimSAS x8 (720 mm)