1 x SAS/SATA + 2 x AnyBay backplanes
This section lists the required components for server models with 1 x SAS/SATA + 2 x AnyBay 2.5-inch hot-swap backplanes.
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.
Y-cables are shown as individual cables in the illustrations for each backplane.
Connect cables prioritizing Gen 4 RAID adapters.
For more information on the cables that are used, see Backplane cable list.
Onboard NVMe/SATA + 2 x retimers + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 1. NVMe cable routing to system board and top PCIe zone ![]() Figure 2. NVMe cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 3. SAS/SATA cable routing to system board and top PCIe zone ![]() Figure 4. SAS/SATA cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe/SATA + 2 x retimers + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 5. NVMe cable routing to system board and top PCIe zone ![]() Figure 6. NVMe cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 7. SAS/SATA cable routing to system board and PCIe slot 9 ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 2 x retimers + 3 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 8. NVMe cable routing to system board and top PCIe zone ![]() Figure 9. NVMe cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 10. SAS/SATA cable routing to top PCIe zone ![]() Figure 11. SAS/SATA cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 2 x retimers + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 12. NVMe cable routing to system board and top PCIe zone ![]() Figure 13. NVMe cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 14. SAS/SATA cable routing to top PCIe zone ![]() Figure 15. SAS/SATA cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 2 x retimers + 1 x 32i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 16. NVMe cable routing to system board and top PCIe zone ![]() Figure 17. NVMe cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 18. SAS/SATA cable routing to PCIe slot 9 ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i G4: C0 | SlimSAS x8 to SlimSAS x8 (720 mm) |
2 BP2: SAS/SATA | 32i G4: C1 | SlimSAS x8 to SlimSAS x8 (720 mm) |
3 BP3: SAS/SATA | 32i G4: C2 | SlimSAS x8 to SlimSAS x8 (720 mm) |
Onboard SATA + 4 x retimers + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 19. NVMe cable routing to top PCIe zone ![]() Figure 20. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 21. SAS/SATA cable routing to system board and top PCIe zone ![]() Figure 22. SAS/SATA cable routing to system board and bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard SATA + 4 x retimers + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 23. NVMe cable routing to top PCIe zone ![]() Figure 24. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 25. SAS/SATA cable routing to system board and PCIe slot 9 ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
Onboard SATA + 4 x retimers + 1 x CFF 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 26. NVMe cable routing to top PCIe zone ![]() Figure 27. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 28. SAS/SATA cable routing to system board and CFF RAID/HBA adapter ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3, 4-7 (onboard) | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
2 BP2: SAS/SATA | CFF RAID/HBA: C0, C1 | SlimSAS x4*2 to SlimSAS x8 (260 mm/260 mm) |
3 BP3: SAS/SATA | CFF RAID/HBA: C2, C3 | SlimSAS x4*2 to SlimSAS x8 (430 mm/430 mm) |
4 x retimers + 3 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 29. NVMe cable routing to top PCIe zone ![]() Figure 30. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 31. SAS/SATA cable routing to top PCIe zone ![]() Figure 32. SAS/SATA cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
4 x retimers + 1 x 8i RAID/HBA + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 33. NVMe cable routing to top PCIe zone ![]() Figure 34. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 35. SAS/SATA cable routing to top PCIe zone ![]() Figure 36. SAS/SATA cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
4 x retimers + 1 x 32i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 37. NVMe cable routing to top PCIe zone ![]() Figure 38. NVMe cable routing to bottom PCIe zone ![]() | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 | |
5 BP2: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
6 BP2: NVMe 2-3 | Retimer: C1 | |
7 BP2: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
8 BP2: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 39. SAS/SATA cable routing to PCIe slot 9 ![]() | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i G4: C0 | SlimSAS x8 to SlimSAS x8 (720 mm) |
2 BP2: SAS/SATA | 32i G4: C1 | SlimSAS x8 to SlimSAS x8 (720 mm) |
3 BP3: SAS/SATA | 32i G4: C2 | SlimSAS x8 to SlimSAS x8 (720 mm) |