1 x SAS/SATA + 1 x NVMe backplane
This section lists the required components for server models with 1 x SAS/SATA + 1 x NVMe 2.5-inch hot-swap backplane.
Note
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.
Y-cables are shown as individual cables in the illustrations for each backplane.
Connect cables prioritizing Gen 4 RAID adapters.
For more information on the cables that are used, see Backplane cable list.
This configuration contains the following combinations:
Onboard NVMe + 1 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 1. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 2. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP2: SAS/SATA |
|
|
Onboard NVMe + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 3. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 4. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP2: SAS/SATA |
|
|
Onboard NVMe + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 5. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 6. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP2: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x8 (640 mm) |
Onboard NVMe + 1 x 32i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 7. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to SlimSAS x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP1: NVMe 4-5 | PCIe 3 (onboard) | SlimSAS x8 to SlimSAS x8 pair (325 mm/160 mm) |
4 BP1: NVMe 6-7 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 8. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP2: SAS/SATA | 32i G4: C0 | SlimSAS x8 to SlimSAS x8 (720 mm) |
2 x retimers + 1 x CFF RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 9. NVMe cable routing to top PCIe zone Figure 10. NVMe cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP1: NVMe 4-5 | Retimer: C0 | SlimSAS x8 to SlimSAS x8 pair (700 mm/700 mm) |
4 BP1: NVMe 6-7 | Retimer: C1 |
SAS/SATA cable routing | ||
---|---|---|
Figure 11. SAS/SATA cable routing to CFF RAID/HBA adapter | ||
From | To | Cable |
1 BP2: SAS/SATA | CFF RAID/HBA: C0, C1 | SlimSAS x4*2 to SlimSAS x8 (260 mm/260 mm) |
Give documentation feedback