Skip to main content

SAS/SATA combinations

See this topic to locate the combination with SAS/SATA backplanes.

Note
  • Secure unused end of Y-cable under the cable clip.

BP1/BP12

HW 8i/16i(BP1)

Table 1. 3.5-inch drive cable routing - HW RAID 8i/16i (BP1)
FromTo
1
8i/16i adapter
  • G4: C0
  • G3: C0, C1
  • 1b NA (contain it in cable clip)
  • 1a SAS/SATA, BP1

HW 8i/16i (BP12)

Table 2. 3.5-inch drive cable routing - HW RAID 8i/16i (BP12)
FromTo
1
8i/16i adapter
  • G4: C0
  • G3: C0, C1
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1

SW RAID (BP1/BP12)

Table 3. 3.5-inch drive cable routing - Onboard SW RAID (BP1/BP12)
FromTo
  • 2 NA
  • 1 SATA 0-3, system board
  • 2 NA
  • 1 SAS/SATA, BP1
  • 2 SATA 4-7, system board
  • 1 SATA 0-3, system board
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1

BP123/BP1234

HW 8i (BP123)

Table 4. 3.5-inch drive cable routing - HW RAID 8i (BP123)
FromTo
2
  • 8i G4: C0
  • 8i G3: C0, C1
1
  • 8i G4: C0
  • 8i G3: C0, C1
  • 2b NA (contain it in cable clip)
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1

HW 8i (BP1234)

Table 5. 3.5-inch drive cable routing - HW RAID 8i (BP1234)
FromTo
2
  • 8i G4: C0
  • 8i G3: C0, C1
1
  • 8i G4: C0
  • 8i G3: C0, C1
  • 2b SAS/SATA, BP4
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1

HW 16i (BP123)

Table 6. 3.5-inch drive cable routing - HW RAID 16i (BP123)
FromTo
2
  • 16i G4: C1
  • 16i G3: C2, C3
1
  • 16i G4: C0
  • 16i G3: C0, C1
  • 2b NA (contain it in cable clip)
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1

HW 16i (BP1234)

Table 7. 3.5-inch drive cable routing - HW RAID 16i (BP1234)
FromTo
2
  • 16i G4: C1
  • 16i G3: C2, C3
1
  • 16i G4: C0
  • 16i G3: C0, C1
  • 2b SAS/SATA, BP4
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1

CFF (BP123/BP1234)

Table 8. 3.5-inch drive cable routing - Internal CFF RAID (BP123/BP1234)
FromTo
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 NA
  • 3 C2, CFF RAID
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 NA
  • 3 SAS/SATA, BP3
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 C3, CFF RAID
  • 3 C2, CFF RAID
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 SAS/SATA, BP4
  • 3 SAS/SATA, BP3
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1