Skip to main content

Mixed combinations

See this topic to locate the combination with SAS/SATA and AnyBay backplanes.

Note
  • Secure unused end of Y-cable under the cable clip.

Onboard SW RAID and VROC combinations

OBSW (BP12); VROC (BP4)

Table 1. 3.5-inch drive cable routing - OBSW (BP12); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2 SATA 4-7, system board
  • 1 SATA 0-3, system board
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • BP4: NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA

OBSW (BP12); VROC (BP3)

Table 2. 3.5-inch drive cable routing - OBSW (BP12); VROC (BP3)
NVMe drives
FromToBackplanes
  • 4 NA
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 4 NA
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • (empty)
  • BP3: NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2 SATA 4-7, system board
  • 1 SATA 0-3, system board
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • (empty)
  • BP3: NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA

8i and VROC combinations

8i (BP12); VROC (BP3)

Table 3. 3.5-inch drive cable routing - 8i (BP12); VROC (BP3)
NVMe drives
FromToBackplanes
  • 4 NA
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 4 NA
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • (empty)
  • BP3: NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 1
  • C0 C1, HW RAID 8i
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • (empty)
  • BP3: NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA

8i (BP12); VROC (BP4)

Table 4. 3.5-inch drive cable routing - 8i (BP12); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 1
  • C0 C1, HW RAID 8i
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • BP4: NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA

8i (BP123); VROC (BP3)

Table 5. 3.5-inch drive cable routing - 8i (BP123); VROC (BP3)
NVMe drives
FromToBackplanes
  • 4 NA
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 4 NA
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C0 C1, HW RAID 8i
  • 1
  • C0 C1, HW RAID 8i
  • 2b NA (contain it in cable clip)
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA

8i (BP124); VROC (BP4)

Table 6. 3.5-inch drive cable routing - 8i (BP124); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C0 C1, HW RAID 8i
  • 1
  • C0 C1, HW RAID 8i
  • 2b SAS/SATA, BP4
  • 2a NA (contain it in cable clip)
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA

8i (BP1); VROC (BP234)

Table 7. 3.5-inch drive cable routing - 8i (BP1); VROC (BP234)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 2 PCIe 4, system board
  • 2 PCIe 3, system board
  • 1 C0, Retimer
  • 1 C1, Retimer
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • 2 NVMe 0-1, BP2
  • 2 NVMe 2-3, BP2
  • 1 NVMe 0-1, BP1
  • 1 NVMe 2-3, BP1
  • BP4: NVMe
  • BP3: NVMe
  • BP2: NVMe
  • BP1: SAS/SATA/NVMe
SAS/SATA drives
FromToBackplanes
  • 1
  • C0 C1, HW RAID 8i
  • 1b NA (contain it in cable clip)
  • 1a SAS/SATA, BP1
  • BP4: NVMe
  • BP3: NVMe
  • BP2: NVMe
  • BP1: SAS/SATA/NVMe

16i and VROC combinations

16i (BP123); VROC (BP3)

Table 8. 3.5-inch drive cable routing - 16i (BP123); VROC (BP3)
NVMe drives
FromToBackplanes
  • 4 NA
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 4 NA
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C2 C3, HW RAID 16i
  • 1
  • C0 C1, HW RAID 16i
  • 2b NA (contain it in cable clip)
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA

16i (BP124); VROC (BP4)

Table 9. 3.5-inch drive cable routing - 16i (BP124); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C2 C3, HW RAID 16i
  • 1
  • C0 C1, HW RAID 16i
  • 2b SAS/SATA, BP4
  • 2a NA (contain it in cable clip)
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA

16i (BP123); VROC (BP4)

Table 10. 3.5-inch drive cable routing - 16i (BP123); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3NA
  • BP4: NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C2 C3, HW RAID 16i
  • 1
  • C0 C1, HW RAID 16i
  • 2b NA (contain it in cable clip)
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • BP4: NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA

16i (BP1234); VROC (BP4)

Table 11. 3.5-inch drive cable routing - 16i (BP1234); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 2
  • C2 C3, HW RAID 16i
  • 1
  • C0 C1, HW RAID 16i
  • 2b SAS/SATA, BP4
  • 2a SAS/SATA, BP3
  • 1b SAS/SATA, BP2
  • 1a SAS/SATA, BP1
  • BP4: SAS/SATA/NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA

Internal CFF and VROC combinations

CFF (BP124); VROC (BP4)

Table 12. 3.5-inch drive cable routing - CFF (BP124); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 C3, CFF RAID
  • 3 NA
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 SAS/SATA, BP4
  • 3 NA
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • BP4: SAS/SATA/NVMe
  • (empty)
  • BP2: SAS/SATA
  • BP1: SAS/SATA

CFF (BP123); VROC (BP3)

Table 13. 3.5-inch drive cable routing - CFF (BP123); VROC (BP3)
NVMe drives
FromToBackplanes
  • 4 NA
  • 3 PCIe 5, system board
  • 3 PCIe 6, system board
  • 4 NA
  • 3 NVMe 0-1, BP3
  • 3 NVMe 2-3, BP3
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 NA
  • 3 C2, CFF RAID
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 NA
  • 3 SAS/SATA, BP3
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • (empty)
  • BP3: SAS/SATA/NVMe
  • BP2: SAS/SATA
  • BP1: SAS/SATA

CFF (BP123); VROC (BP4)

Table 14. 3.5-inch drive cable routing - CFF (BP123); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 NA
  • 3 C2, CFF RAID
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 NA
  • 3 SAS/SATA, BP3
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • BP4: NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA

CFF (BP1234); VROC (BP4)

Table 15. 3.5-inch drive cable routing - CFF (BP1234); VROC (BP4)
NVMe drives
FromToBackplanes
  • 4 PCIe 1, system board
  • 4 PCIe 2, system board
  • 3 NA
  • 4 NVMe 0-1, BP4
  • 4 NVMe 2-3, BP4
  • 3 NA
  • BP4: SAS/SATA/NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA
SAS/SATA drives
FromToBackplanes
  • 6
  • Signal connector, CFF
  • 5 Power connector, CFF
  • 4 C3, CFF RAID
  • 3 C2, CFF RAID
  • 2 C1, CFF RAID
  • 1 C0, CFF RAID
  • 6a PCIe 3 or 6b PCIe 2, system board
  • (6b not applicable to 440-16i)
  • 5 CFF power connector, system board
  • 4 SAS/SATA, BP4
  • 3 SAS/SATA, BP3
  • 2 SAS/SATA, BP2
  • 1 SAS/SATA, BP1
  • BP4: SAS/SATA/NVMe
  • BP3: SAS/SATA
  • BP2: SAS/SATA
  • BP1: SAS/SATA