Removing the hard disk drive fan duct
This procedure applies only to the 5U server model with hot-swap power supplies (Model name: 2582-F4x).
To remove the hard disk drive fan duct on the 5U server model with hot-swap power supplies (Model name: 2582-F4x), complete the following steps.
- Turn off the server and all attached devices; then, disconnect all power cords and external cables.
- Unlock and remove the side cover (see Removing the side cover).
- Carefully turn the server on its side so that it is lying flat, with the system board facing up.AttentionDo not allow the server to fall over.
- Unfasten the retention clips that secure the hard disk drive fan duct cable and then disconnect the hard disk drive fan duct cable from the system board.
- Grasp the hard disk drive fan duct by the blue point and pull up to lift it out of the chassis.
- If you are instructed to return the fan, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
Give documentation feedback