Skip to main content

Installing a simple-swap hard disk drive

Use this information to install a simple-swap hard disk drive into the server.

To install a simple-swap hard disk drive, complete the following steps:

  1. Read the safety information that begins in Safety and Installation guidelines.
  2. Turn off the server (see Turning off the server) and all attached peripheral devices. Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
  3. If installing a new drive, touch the static-protective package that contains the new drive to any unpainted metal surface on the server; then, remove the drive from the package and place it on a static-protective surface.
  4. Remove the filler panel from the front of the server.
  5. Gently push the drive assembly into the drive bay until the drive clicks into place.

  6. Install the filler panel.
  7. If you are installing additional simple-swap drives, do so now.
  8. Restart the server. Confirm that it starts correctly and recognizes the newly installed devices, and make sure that no error LEDs are lit.
    Note
    If the server is configured for RAID operation using a ServeRAID adapter, you might have to reconfigure your disk arrays after you install drives. See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter.

If you have other devices to install or remove, do so now. Otherwise, go to Completing the installation.