cin command errors
This topic lists error messages for the cin command.
See Common errors for a list of error messages that apply to all commands. See cin command for information about command syntax and examples of command use.
Error message | Definition |
---|---|
-id cannot be the same as the blade management VLAN ID. Please try again. | A user tries to enter a command with a VLAN ID which is the same as the VLAN ID of the compute node management. |
-ip cannot be multicast. Please try again. | A user issues a command with an IP address which is the same as the IP address of the multicast. |
-ip cannot be the same as the CMM IP address. Please try again | A user tries to enter a command with an IP address which is the same as the IP address of the CMM. |
An error occurred while changing CIN global status setting | An error occurs while user is changing CIN global status setting. |
An error occurred while clearing CIN entry | An error occurs while the user is clearing a CIN entry. |
An error occurred while enabling/disabling CIN entry. | An error occurs while the user is enabling/disabling a CIN entry. |
An error occurred while setting CIN entry. | An error occurs while configuring a CIN entry. |
Both -id and -ip are required for adding a CIN entry. | A user tries to enter a command to add an entry without both -id and -ip options. |
CIN blade pair TLV get failed | An error occurs while the CMM is getting CIN compute node configuration parameters. |
CIN global TLV get failed. | An error occurs while the CMM is getting a CIN global configuration parameter. |
CIN command failed. | An error occurs while the CMM is executing a CIN command. |
cin -index -en state cannot be used with other options. where
| The user tries to enter a command with the -en option with along with other options. |
Duplicate CIN (-id, 0.0.0.0) pairs are not allowed. Please try again. | A user tries to enter a command with a duplicated -id/0.0.0.0 pair. |
Duplicate -ip is not allowed. Please try again. | A user tries to enter a command with a duplicated IP address. |
Getting CMM failed | System is unable to locate a CMM. |
Internal error checking CIN entry. | An error occurs while the system checks user input for the CIN entry configuration. |
Internal error getting CIN entry | An error occurs while the CMM is getting CIN entry configuration parameters. |
Invalid index parameter. Input must be numeric. | A user tries to enter a command with a non-numeric index. |
Invalid index parameter. Input out of range. | A user tries to enter a command with an index which is out of range. |
Invalid IP argument for an option. Enter 4 bytes separated by 3 dots. | A user tries to enter a command argument for IP address option which is invalid because it is too long, too short, or not numeric. |
Invalid IP argument for an option. Too many bytes. | A user tries to enter a command with an invalid argument for IP address option which has more than four parts. |
Invalid IP argument for an option. Too few bytes | A user tries to enter a command with an invalid argument for IP address option which has fewer than four parts. |
Invalid IP argument for an option. Each byte has to be in the range (0-255). | A user tries to enter a command with an invalid argument for IP address option, each part of which is not in the range of 0-255. |
Invalid option argument for -global -en: | A user issues a command with an invalid argument for -global -en option. |
No CMM found | System is unable to locate a CMM. |
No primary CMM found | System is unable to locate the primary CMM. |
Give documentation feedback