Removing and replacing Tier 1 CRUs
Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation.
The illustrations in this document might differ slightly from your hardware.
- Removing a RAID adapter battery
Use this information to remove a remotely installed RAID adapter battery. - Replacing a RAID adapter battery
Use this information to replace a RAID adapter battery. - Removing a RAID adapter battery holder
Use this information to remove a RAID adapter battery holder. - Replacing a RAID adapter battery holder
Use this information to install a RAID adapter battery holder. - Removing the optional front 2.5-inch hot-swap hard disk drive cage
Use this information to remove the optional front 2.5-inch hot-swap hard disk drive cage. - Installing the optional front 2.5-inch hot-swap hard disk drive cage
Use this information to install the optional front 2.5-inch hot-swap hard disk drive cage. - Removing the IMM interposer assembly
Use this information to remove the IMM interposer assembly. - Replacing the IMM interposer assembly
Use this information to install the IMM interposer assembly. - Removing the power paddle card from the GPU tray
Use this information to remove the paddle card from the GPU tray. - Replacing the power paddle card on to the GPU tray
Use this information to install the power paddle card on to the GPU tray. - Removing the system battery
Use this information to remove the CMOS battery. - Replacing the system battery
- Removing a memory module
Use this information to remove a memory module. - Installing a memory module
The following notes describe the types of DIMMs that the compute node supports and other information that you must consider when you install DIMMs. - Removing the hard disk drive backplate
Use this information to remove the hard disk drive backplate. - Installing the hard disk drive backplate
Use this information to install the hard disk drive backplate. - Removing and installing drives
Use this information to remove and install drives. - Removing a ML2 riser-cage assembly
- Replacing a ML2 riser-cage assembly
- Removing a PCI riser-cage assembly
- Replacing a PCI riser-cage assembly
- Removing a PCI riser-cage assembly from the GPU tray
- Replacing a PCI riser-cage assembly to the GPU tray
- Removing a PCI riser-cage assembly from the 2U GPU tray
- Replacing a PCI riser-cage assembly to the 2U GPU tray
- Removing an adapter/GPU adapter
Use this information to remove an adapter/GPU adapter. - Replacing an adapter/GPU adapter
The following notes describe the types of adapters that the server supports and other information that you must consider when you install an adapter. - Removing the SD adapter
Use this information to remove the SD adapter. - Replacing the SD adapter
Use this information to replace a SD adapter. - Removing a ServeRAID SAS/SATA controller
Use this information to remove a ServeRAID SAS/SATA controller. - Replacing a ServeRAID SAS/SATA controller
Use this information to replace a ServeRAID SAS/SATA controller. - Removing the USB flash drive
Use this information to remove the USB flash drive. - Installing the USB flash drive
Use this information to install the USB flash drive.
Give documentation feedback