Skip to main content

Remove the network board (trained technician only)

Use this information to remove the network board.

About this task

Required tools

Make sure you have the required tools listed below in hand to properly replace the component.

  • Water loop kits

    • SD650-N V3 Water Loop Gap Pad Kit (The water loop carrier in the Service Kit is reusable, it is recommended to keep it at the facility where the server operates for future replacement needs.)

    • SD650-N V3 Water Loop Putty Pad Kit

    • SD650-N V3 SXM5 PCM Fixture

    • SXM5 PCM Kit

  • Screws and screwdrivers

    Prepare the following screwdrivers to ensure you can install and remove corresponding screws properly.
    Screw TypeScrewdriver Type
    Hex screwdriver6 mm hex head screwdriver
    Torx T10 screwTorx T10 head screwdriver
    Torx T15 screwTorx T15 head screwdriver
    Phillips #1 screwPhillips #1 head screwdriver
    Phillips #2 screwPhillips #2 head screwdriver
Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Turn off the corresponding DWC tray that you are going to perform the task on.

  • Disconnect all external cables from the enclosure.

  • Use extra force to disconnect QSFP cables if they are connected to the solution.

  • To avoid damaging the water loop, always use the water loop carrier when removing, installing or folding the water loop.

  • A torque screwdriver is available for request if you do not have one at hand.

Watch the procedure
  • A video of this procedure is available at YouTube.

Procedure

  1. Make preparations for this task.
    1. Remove the tray from the enclosure. See Remove a DWC tray from the enclosure.
    2. Remove the tray cover. See Remove the tray cover.
    3. Remove the cross braces. See Remove the cross braces.
    4. Remove the bus bar. See Remove the bus bar.
    5. Remove the MCIO cables. Follow the guidance and routing information in Internal cable routing.
  2. Disconnect the OSFP module cables from the network board on the GPU node.
    CAUTION
    • Hold the cable connector at 45 degree angle when inserting it into the port.

    • Have extremely precaution when reseating the connectors that have a 45 degree label on them as they are fragile and will get damage if not installed in the correct 45 degree angle.



    Figure 1. Disconnecting OSFP module cables from the network board
    Disconnecting OSFP module cables from the network board
    From

    OSFP module connectors

    To

    Network board connectors

    1 Network connector (near GPU node)1 Port 0
    2 Power connector P12 OOB port 0
    3 Power connector P23 OOB port 1 (on network board) and power connector (on carrier board)
    4 Network connector (near Compute node)4 Port 1
    5 Stud (in between the nodes) Make sure the cables are routed around the stud as shown in the illustration.
  3. Remove the carrier board power cable from the GPU node.
    Figure 2. Carrier board power cable removal

    From (carrier board)To (GPU node power distribution board)
    1 Power and side band connector1 Power connector
  4. Remove cable tie from the GPU board.
    Figure 3. Cable tie removal
    Cable tie removal
  5. Remove the Hex screw (x1) and the PH1 screws (x3) from the water loop with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 5.0+/- 0.5 lbf-in, 0.55+/- 0.05 N-M.
    Figure 4. Water loop Hex and PH1 screws removal (GPU node)
    Water loop Hex and PH1 screws removal (GPU node)
  6. Remove water loop screws and quick connect screws (x11 Torx T10 screws) with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 5.0+/- 0.5 lbf-in, 0.55+/- 0.05 N-M.
    Figure 5. Water loop Torx T10 screws removal (GPU node)
    Water loop Torx T10 screws removal (GPU node)
  7. Remove the quick connect screws (x4 Torx T10) with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 5.0+/- 0.5 lbf-in, 0.55+/- 0.05 N-M.
    Figure 6. Quick connect screw removal (GPU node)
    Quick connect screw removal (GPU node)
  8. Follow the screw removal sequence specified on the network board label, and remove network cold plate screws (x8 Torx T10 screws) with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 5.0+/- 0.5 lbf-in, 0.55+/- 0.05 N-M.
    Figure 7. Network card screw removal
    Network card screws removal
  9. Loosen GPU cold plate screws (x16 Torx T10 screws) in the diagonal pattern with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/loosened is 0.4+/-0.05 N-m, 3.5+/-0.5 lb-In.
    Figure 8. Loosening GPU cold plate screw
    Loosening GPU cold plate screw removal
  10. Release the front and rear MISC conduction plates of the water loop from the GPU board.
    1. Insert a flat head screwdriver into the gaps between the MISC conduction plates (front and rear) and the GPU board. Then, slightly rotate the flat head screwdriver.
      Note
      Locations of the gaps for inserting flat head screwdriver is shown in the illustration below.
    2. The front and rear MISC conduction plates release from the GPU board slightly.
      Figure 9. Releasing the front and rear MISC conduction plates release from the GPU board
      Releasing the front and rear MISC conduction plates release from the GPU board
  11. Release the GPU cold plates from the GPUs.
    1. There are notches on the sides of the GPU cold plates for inserting a flat head screwdriver. The locations of the notches are shown in the illustration below.
      Attention
      Inserting the flat head screwdriver ONLY to the notches circled in the illustration below. Otherwise, the screwdriver may damage the GPUs.
      Figure 10. Notches for releasing GPU cold plates
      Notches for releasing GPU cold plates
    2. Insert a flat screwdriver into all the notches shown in the illustration; then, slightly rotate the screwdriver to release the GPU cold plates from the GPUs.
      Figure 11. Releasing the GPU cold plate from the GPU
      Releasing the GPU cold plate from the GPU
  12. Gently put the water loop carrier down onto the water loop and ensure it is seated firmly on the water loop.
    Figure 12. Water loop carrier installation (GPU node)
    Water loop carrier installation (GPU node)
  13. Tighten water loop carrier screws (x20 Phillips #2 screws) with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 5.0+/- 0.5 lbf-in, 0.55+/- 0.05 N-M.
    Figure 13. Tightening water loop carrier screws (GPU node)
    Tightening water loop carrier screws (GPU node)
  14. Carefully rotate the GPU node side water loop so that it is sitting on top of the Compute node side water loop.
    Figure 14. Folding the GPU node side water loop onto the Compute node side water loop
    Folding the GPU node side water loop onto the Compute node side water loop
  15. Immediately clean the PCM off all the GPUs with alcohol cleaning pads. Gently clean the PCM to avoid GPU damages.
    Attention
    • It is recommended to clean the PCM while it is in liquid state.

    • The electrical components around the die on the GPUs are extremely delicate. When removing the PCM and cleaning the GPU die, avoid touching the electrical components to prevent damages.

    Figure 15. Cleaning PCM off from all GPUs
    Cleaning PCM off from all GPUs
  16. With alcohol cleaning pads, wipe off any remaining putty pad and PCMs from the water loop and components in the GPU node.
    Figure 16. Cleaning putty pads from water loop
    Cleaning putty pads from water loop
    Figure 17. Cleaning putty pads and PCM from the components in the GPU node

  17. Follow the sequence shown in the illustration below to remove the network board screws (x4 Torx T15 screws) with a torque screwdriver set to the proper torque.
    Note
    For reference, the torque required for the screws to be fully tightened/removed is 0.9 newton-meters, 7.96 inch-pounds.
    Figure 18. Network board screws removal
    Network board screws removal
  18. Remove the network board from the GPU node.
    Figure 19. Removing the network board
    Removing the network board
After you finish

If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo video

Watch the procedure on YouTube