Skip to main content

Install the rear dust filter

Follow instructions in this section to install the rear dust filter.

About this task

Attention
Important

With air flow sensor board installed, SE360 V2 BMC supports dust filter measurement feature to check the status of the rear dust filter. Log in to Lenovo XClarity Controller web interface, and go to Utilization > Fan Speed (RPM) > Dust Filter Measurement to take the measurement by selecting Run immediately (once), or by setting a regular schedule. See Set dust filter measurement for more information.

  • When taking the measurement, the fans will operate at full fan speed for about 30 seconds.
  • After taking the measurement, see Lenovo XClarity Controller Event Log for the status of rear dust filter. For proper operation, replace the rear dust filter according to the action suggestions in the generated event.

SE360 V2 supports a dust filter installed at rear of the node. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.

Procedure

  1. Place the dust filter into the chassis.
    Figure 1. Installing the dust filter

  2. Align the rear bezel with the chassis; then, fasten the two captive screws to secure the bezel.
    Figure 2. Installing the bezel

After this task is completed

Complete the parts replacement. See Complete the parts replacement.