Understanding the technical rules for drives helps you correctly install and configure drives in the system.
Drive installation rules
The following rules for drives provide information that you must consider when you install a drive.
General rules
The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the installation order when you install a drive. See Front view for more details.
The drives in a single RAID array must be of the same type (as in hard disk drives, solid-state drives, and so on), same size, and same capacity.
If your server comes with rear drives, always install the rear backplane first. The drive installation should be rear drive bay 16 → 17, and then front drive bay 0 → 1 → 2 → 3 → 4 → 5 → 6 → 7 → 8 → 9.
The installation order of different drive interface types: NVMe → SAS → SATA.
For EDSFF drives, follow the numerical order of the drive bay sequence. Do not skip bays when installing EDSFF drives.
Mixing rules
You can use drives from different vendors.
You can mix drives of different types and different capacities in one system, but not in one RAID array. And when you deploy a drive mix, install drives of lower capacity first.
You can install a 2.5-inch solid-state/SAS/SATA drive in a 3.5-inch hard disk drive bay.
When mixing NVMe/SAS/SATA drives in one system, install NVMe drives in a descending bay sequence order, 9 → 8 →7...; and SAS/SATA drives in an ascending bay sequence order, 0 → 1 → 2....
Mixing EDSFF, U.2 or U.3 drives in one RAID array is not supported.
M.2 and 7mm drives are not supported at the same time.
ThinkSystem M.2 SATA/x4 NVMe 2-Bay Enablement Kit cannot be supported on a 3.5'' chassis.
ThinkSystem M.2 RAID B540i-2i SATA/NVMe Enablement Kit cannot be supported with other M.2 kits at the same time.
Special notes
For the server models with a single type or mixed types of drives, take 10 x 2.5'' AnyBay drives for instance:
The installation order of a single type of drives (SAS/SATA/NVMe) should be: front drive bay 0 → 1 → 2 → 3 → 4 → 5 → 6 → 7 → 8 → 9.
The installation order of mixed types of drives should be: SAS/SATA installed from front drive bay 0 → 1 → 2..., and NVMe installed from front drive bay 9 → 8 →7 → 6 → 5→ 4 → 3 → 2 → 1 → 0.
For the server models with rear drives installed, take 8 x 2.5'' SAS/SATA front drives and 2 x 2.5'' SAS/SATA rear drives for instance:
Drives can be installed to rear drive bay 16 → 17 first, and then front drive bay 0 → 1 → 2 → 3 → 4 → 5 → 6 → 7.
- VMware ESXi does not support:
ThinkSystem 2.5 U.3 6500 ION 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
ThinkSystem 2.5" U.2 P5336 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
ThinkSystem 2.5" U.2 P5336 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
ThinkSystem 2.5" U.2 P5336 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD
ThinkSystem 2.5" U.2 P5336 61.44TB Read Intensive NVMe PCIe 4.0 x4 HS SSD